12
D.6
Storage
The machine and/or its parts must be stored and protected
from damp, in a non-aggressive place, free of vibrations and
with room temperatures between -10
℃
and 50
℃
. The place
where the machine is stored must have a flat support surface
to avoid deforming the machine or damage to the support feet.
WARNING
Appliance positioning, installa-
tion and disassembly must be
carried
out
by
specialised
personnel.
CAUTION
Do not make modifications to the parts
supplied with the appliance. Any missing
or faulty parts must be replaced with
original parts.
E
INSTALLATION AND ASSEMBLY
E.1
Introduction
To ensure correct operation of the appliance and maintain safe
conditions during use, carefully follow the instructions given
below in this section.
WARNING
The above operations must be
carried out by the specialised
personnel in conformity with the
current
safety
regulations,
regarding the equipment used
and the operating procedures.
Before moving the appliance
make sure the capacity of the
lifting equipment used is suitable
for its weight.
E.2
Customer responsibilities
The Customer must provide for the following:
• installation of an adequate electrical power supply ahead of
the appliance, according to the equipment’s technical
specifications (C.1
Main technical characteristics
and C.2
Characteristics of power supply
);
• the equipotential connection
of the workplace electrical
system to the metal structure of the machine by means of a
copper cable of adequate section (see position “EQ“ in
• adducting for the electrical connection between the work-
place electric panel and the equipment;
• the water supply and drain connections and other con-
nections as indicated in C.1
Main technical characteristics
and in the paragraph E.8
;
E.3
Characteristics of the installation place
The machine is designed for installation in professional and
not domestic-type kitchens. Water collection traps/ metal
grates must be arranged in the floor at the machine discharges
(see the
), possibly replaceable with a
single water trap sized for a flow rate of at least 3 l/s.
CAUTION
Do not install the appliance over 2000
meters above sea level.
E.4
Appliance space limits
• A suitable space must be left around the appliance (for
operations, maintenance, etc.).
• The passages enabling personnel to operate on the
appliance must be at least 50 cm wide, except at the rear
of the appliance.
• This space must be increased in case of use and/or transfer
of other equipment and/or means or if exit routes are
necessary inside the workplace.
• To be used to keep the correct distances indicated in the
installation diagram.
E.5
Positioning
The machine must be taken to the place of installation and the
packing base removed only when being installed.
Arranging the machine:
• Wear protective gloves and unpack the machine.
• Lift equipment with a lift truck, inserting the forks as
indicated below, remove the base and position the appli-
ance where it is to be installed.
3
2
1
3
2
1
3
2
1
3
2
1