10
C
TECHNICAL DATA
C.1
Main technical characteristics
Model
EPPWA060
Power supply
Electric
Supply voltage:
convertible to
400V 3N~
230V 3~
Frequency
Hz
50
Max. power
kW
20
1
Power absorbed as factory setting
kW
13
Boiler heating elements
kW
10.5
Tank heating elements
kW
7
Water supply pressure
kPa
[bar]
50 - 700
[0.5 - 7]
Water supply temperature
℃
[
℉
]
50
[122]
Water supply hardness for models without incorpo-
rated continuous water softener
°f/°d/°e
14/8/10 max
Rinse cycle water consumption
l
7
Boiler capacity
l
18
Tank capacity
l
95
Standard cycle time with water supply at 50
℃
[122
℉
]
sec.
180(for wash cycle 1)
360 (for wash cycle 2)
480 (for wash cycle 3)
Legal noise level Leq for single wash pump
2
dB[A]
LpA:74.9dB
KpA:1.5dB
Legal noise level Leq for double wash pump
dB[A]
LpA:77.2dB
KpA:1.5dB
Protection rating
IPX5
Net weight
kg
200
Power supply cable
H07RN-F
1.
If activated by software, coincidence of tank and boiler heating elements.
2.
The noise emission values have been obtained according to EN ISO 11204.
380 – 415V 3N
220 – 230V 3
C
S
C
S
13 kW
20 kW
5x4 mm
2
5x6 mm
2
25A 3P + N
40A 3P + N
4x10 mm
2
4x16 mm
2
50A 3P
60A 3P
C = Power supply cable
S = On/Off switch
NOTE!
Standard cycle time may vary should the inlet water temperature and/or the boiler heating elements be different from
that indicated above.
C.2
Characteristics of power supply
The AC power supply to the machine must meet the following conditions:
• max. voltage variation ± 6%
• max. frequency variation ± 1% continuous ± 2% for a short period.
Harmonic distorsion, unbalanced three-phase supply voltage, voltage pulses, interruption, dips and the other electric character-
istics must respect the provisions of point 4.3.2 of Standard EN 60204-1 (IEC 60204-1).
WARNING
The machine's power supply must be protected against overcurrents (short
circuits and overloads) by fuses or suitable thermal magnetic circuit breakers.
A suitable high-sensitivity manual-reset differential omnipolar thermal-
magnetic switch with contact gap enabling complete disconnection in
category III overvoltage conditions and complying with the current regula-
tions, must be installed between the power cable and the electric line.