32
Removal and installation of the runners
For easier cleaning you may remove the entire shelving
parts from the oven inside.
Remove: first press the vertical grid element (1) back-
wards and draw off towards the center of the cavity and
remove (2) from the oven, lift slightly, if need be.
Hang in again: Insert first the rear clevis hook (3), then
the clevis hook in front of the cavity and (4) firmly press
down.
Important: make sure that the grid runners are in the
right position. Grid runners stop positions must be in
front of the cavity and show down to the bottom.
Fold down top
-
heat element
For easier cleaning the heating elements under the
oven ceiling can be folded down at a slant.
Lay both your thumbs to the left and right on the outside
oven frame, then grip with your fingers in the front
bends of the heating elements and draw them off their
fixture to the front. The heating elements can now be
lowered at a slant and you can clean the oven ceiling.
After cleaning move the elements up again, draw in
again with fingers and thumbs and catch into the fix-
ture.
Appliances with stainless steel surface
During the cleaning procedure make sure that
the stainless steel surface finish (the fine hori-
zontal lines) will not be processed against the
structure.
For the stainless steel front side we recommend
throughout and regular cleaning and care with
suitable stainless steel cleaners and preserva-
tive agents.
Please observe manufacturer‘s instructions.
Scratching and scouring agents are not suitable.
Before wiping put the cleaner on a wet cloth and
afterwards wash off with water and dry with a
clean cloth.
4
3
stop position
clevis hook
remove
hang in
2
1