![Electrolux EOG 21300 User Manual Download Page 30](http://html.mh-extra.com/html/electrolux/eog-21300/eog-21300_user-manual_2383366030.webp)
30
electrolux
Minimum level adjustment of
gas oven burner
This procedure must be
undertaken by a competent and
qualified engineer only.
1.
Disconnect the appliance from the
mains supply.
2. Remove the gas oven control knob.
3. Adjust the by-pass screw (“A
A
A
A
A”) using
a thin bladed screwdriver. When
changing from natural gas to liquid
gas, completely tighten the adjustment
screw in.
When changing from liquid gas to
natural gas, undo the by-pass screw
about 3/4 of a turn.
4. Refit the gas oven control knob.
5. Restore the mains supply.
Do not restore the mains
supply if all the removed parts
have not been fitted back in
their original position.
6. Light the oven gas burner (see the
relevant chapter), set the gas oven
control knob on 240 and let the oven
heat for 10 minutes at least.
7. Check that the oven gas burner flame
does not fail when quickly turning the
GAS
INJECTOR NOMINAL
NOMINALGAS
REDUCED
BY-PASS
NOMINAL
TYPE
MARK
GAS
FLOW
GAS
NEEDLE
GAS
1/100 mm
POWER
POWER
(1/100 mm) PRESSURE
(kW)
m
3
/h g/h
(kW)
(mbar)
114
2,7
0,257 -
1,0
Reg.
20
078
2,5
- 182
1,0
52
30
Natural Gas
(G20)
Liquid Gas
(G30/G31)
Gas Oven Burner Data
A
Summary of Contents for EOG 21300
Page 2: ......
Page 35: ...electrolux 35 ...