Electrical connection
The instructions given below are designed
specifically for a qualified installer and should aid
him or her to perform all installation, adjustment,
and maintenance operations with absolute
precision and in compliance with all current
legislation and regulations. We strongly
recommend that all operations for the installation
of your appliance be carryed out by qualified
personnel in accordance with existing rules and
regulations.
The appliance must be earthed.
Terminal block
The oven has an easily accessible terminal block, which is
meant to work with an electric single-phase rate of 230 V.
The manufacturer disclaims any
responsability should all the safety
measures not be carried out.
The oven is designed to be connected to 230 V (50 Hz)
electricity supply.
The oven has an easily accessible terminal block which
is marked as follows.
Letter L
Live terminal
Letter N
Neutral terminal
Earth
Before proceeding to the connection of the oven make
sure that:
- the limiting valve and the domestic electrical circuit
are sufficient to support the load of the appliance (see
identification plate);
- the electrical system is equipped with an earthing
cable in accordance with current norms and legal
provisions;
- the plug or omnipolar switch used to carry out the
connection is easily accessible once the appliance
is installed.
The appliance is supplied with power cable, the
conductors of which have a minimum section of 3x1.5
mm. Besides this, the cable has a normalised plug
suitable for the electrical load indicated on the
identification plate.
The plug should be connected to a suitable elctrical
socket.
If a direct connection to the supply is desired an
omnipolar switch having a minimum opening of 3mm
between the contacts must be installed between the
appliance and the electricity supply; this switch must
be suitable for the electrical load of the appliance and
must conform to the current norms.
The yellow/green earth wire must not be interrupted by
the switch and it shouldbe 2-3 cm longer than the other
cables. In every case the supply cable must be
positioned insuch a way that it can, at no time, reach
temperaures of more than 90°C.
After connection test the heating elements by putting
them into operation for abour 3 minutes.