3 Levels of Electronic Control
3.1 Display Layout for models without remote controlled HBTN:
3.1.1 Basic software functionality
- ON/OFF
switch
-
Soft-start, function according to chapter “Softstart and motor power change”.
-
Automatic 50/60Hz detection.
-
When started, raise power to maximum power.
-
( + ) increase motor power, one press increase power with one step. After maximum power has been
reached, the power stays in maximum power independent further activations of the “+” button.
-
( - ) decrease motor power, one press decrease power with one step. After minimum power has
been reached, the power stays in minimum power independent further activations of the “-” button.
-
5-step power regulation.
-
Power indication by one of five LED indicating actual power step.
-
S-bag and Filter status are indicated by two LED:s.
- Failure
indication.
3.1.2 Motor power regulation and LED-functionality
1.
Main plug connected:
- Motor shall be off.
- Power LED:s indicates standby by turning on each LED for 0,5 seconds each, “walking light”.
Order should be from “Min” to “Max”.
2.
First start (after main plug is connected):
- Motor power starts in Max power position.
- LED indicates “Max” position, with continuous light.
3.
Power setting is changed by “+” or “-“ button:
- Motor power steps up or down.
- LED indication follows the setting of the motor power, with continuous light.
4.
Cleaner is turned off by On/Off switch:
- Motor turns off; last power setting is remembered by the microcontroller.
- LED indication shows the last used power setting by flashing the corresponding LED with 1Hz.
5.
Cleaner is turned on by On/Off switch after being at point 4:
- Motor turns on, and starts at the last used power setting.
- LED indication shows used power setting, with continuous light.
EN Publication
number
599 71 19-22
Rev. 01
02/2009
PR - 28/42