manutenzione
electrolux
19
Alarms
Indicator lights
Message
Fixed yellow
light
The filter is becoming depleted,
2400 litres of water have been
dispensed. Refer to the instructions for
replacing the filter cartridge on the
next page.
Fixed yellow and
red leds
Time to change the filter, 2,800 litres
of water have been dispensed. See
filter cartridge replacement
instructions.
Yellow and red
led blink
together
Dispensing is deactivated, 2,840 litres
have been dispensed. Replace the filter
to reactivate water dispensing. See
filter cartridge replacement
instructions.
Red led flashes
Dispensing is deactivated. The anti-
flooding device is on. To reactivate the
appliance remove the water and dry
the bottom. Switch the appliance off
and then back on.
Yellow led
flashes slowly
Dispensing is deactivated. Pump
protection device is on. To reactivate
the appliance switch it off and then
back on.
Yellow led
flashes fast
Lack of water from the mains. To
eliminate the alarm switch the
appliance off and then back on.