Troubleshooting and Testing
3-6
Procedure
Letter
F
Component Test
5. If the C/T fuse is blown when the door is opened, check the secondary interlock relay, primary
interlock switch and monitor switch according to the “TEST PROCEDURE” for those switches
before replacing the blown monitor fuse.
If the C/T fuse is blown by improper switch operation, the C/T fuse and monitor switch must
be replaced with “C/T fuse and monitor switch assembly”, even if the monitor switch operates
normally. The C/T fuse and monitor switch assembly is
comprised of a 20 ampere fuse and switch.
6. Reconnect all leads removed from components during testing.
7. Reinstall the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
PRIMARY AND THIRD DOOR SWITCH TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor. (See Warnings and Instructions on page 3-1)
4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO)
terminal of the switch. The meter should indicate an open circuit with the door open and a
closed circuit with the door closed. If improper operation is indicated, replace the third door
interlock switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
SECONDARY INTERLOCK SYSTEM TEST DOOR SENSING SWITCH
DOOR SENSING SWITCH
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO)
terminal of the switch. The meter should indicate an open circuit with the door open and a
closed circuit with the door closed. If improper operation is indicated, replace the door sensing
switch.
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
Before replacing a blown CT fuse, test the secondary interlock relay, primary interlock
switch, door sensing switch and monitor switch for proper operation.
If the door sensing switch contacts fail in the open position and the door is closed, the
cooling fan, turntable and oven light will be activated by RY1.