1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the bypass
screw position. If you change from natural
gas 20 mbar (or natural gas 13mbar
2)
) to
liquid gas, fully tighten the adjustment
screw in. If you change from liquid gas to
natural gas 20 mbar, undo the by-pass
screw approximately 1/4 of a turn. If you
change from natural gas 20 mbar to nat-
ural gas 13 mbar
2)
undo the by-pass
screw about 1/4 of a turn. If you change
from liquid gas to natural gas 13 mbar
2)
,
undo the bypass screw about 1/2 of a
turn. If you change from natural gas 13
mbar
2)
to natural gas 20 mbar to tighten
the by-pass screw about 1/4 of a turn.
1
Minimum adjustment screw
5. Make sure the flame does not go out
when you quickly turn the knob from the
maximum position to the minimum posi-
tion.
Electrical connection
• Ground the appliance according to safety
precautions.
1
• Make sure that the rated voltage and type
of power on the rating plate agree with the
voltage and the power of the local power
supply.
• This appliance is supplied with a mains ca-
ble. It has to be supply with a correct plug,
able to support the load marked on the
identification plate. The plug has to be fit-
ted in a correct socket.
• Any electrical component must be instal-
led or replaced by the Service Force Cen-
tre technician or qualified service person-
nel.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to the
mains plug after installation.
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug.
• Connect the appliance to the mains with a
device that lets to disconnect the appli-
ance from the mains at all poles with a
contact opening width of minimum 3 mm,
eg. automatic line protecting cut-out, earth
leakage trips or fuse.
• None of a parts of the connection cable
can not get a temperature 90°C. The blue
neutral cable must be connected to the
terminal block label with "N". The brown (or
black) phase cable (fitted in the terminal
block contact marked with "L") must al-
ways be connected to the live phase.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 type. Make sure that the ca-
ble section is applicable to the voltage and
the working temperature. The yellow/green
earth wire must be approximately 2 cm. lon-
ger than the brown (or black) phase wire.