background image

8

MIDLANDS

BIRMINGHAM

66 Birch Road East

Wyrley Trading Estate

Witton

Birmingham

B6 7DB

BOURNE

Pinfold  Road

Bourne

PE10 9HT

BRIDGNORTH

68 St. Mary’s Street

Bridgnorth

Shropshire

WV16 4DR

GLOUCESTER

101 Rycroft Street

Gloucester

GL1 4NB

HEREFORD

Units 3 & 4

Bank  Buildings

Cattle market

Hereford

HE4 9HX

HIGHAM FERRERS

30 High Street

Higham  Ferrers

Northants

NN10 8PL

ILKESTON

Unit 2

Furnace  Road

Ilkeston   DE7 5EP

LEICESTER

Unit 7

Oaks Industrial Estate

Coventry  Road

Narborough

Leicestershire

LE9 5GF

LINCOLN

Unit 8

Clifton  Street

Stone Field Park

Lincoln

LN5 8LQ

NEWCASTLE

18-21 Croft Road

UNDER LYME

Brampton Ind. Estate

Newcastle under Lyme

Staffordshire

ST5 0TW

REDDITCH

13  Thornhill  Road

North Moons Moat

Redditch

Worcestershire

B98 9ND

TAMWORTH

Unit 3

Sterling  Park

Claymore

Tamworth

B77 5DQ

WORCESTER

Units 1 & 2

Northbrooks  Close

Gregorys Mill Ind. Estate

Worcester

WR3 8BP

LONDON & EAST ANGLIA

BECKENHAM

11a Gardner Ind. Estate

Kent House Lane

Beckenham

Kent    BR3 1QZ

CHELMSFORD

Hanbury  Road

Widford  Ind.  Estate

Chelmsford

Essex

CM12   3AE

COLINDALE

Unit 14

Capitol  Park

Capitol  Way

Colindale

London   NW9 0EQ

ELTHAM

194 Court Road

Mottingham

Eltham

London   SE9 4EW

ENFIELD

284 Alma Road

Enfield

London

EN3 7BB

GRAVESEND

Unit  B4

Imperial Business Estate

West Mill

Gravesend

Kent

DA11 0DL

IPSWICH

Unit  6C

Elton Park Business Centre

Hadleigh  Road

Ipswich

IP2 0DD

LETCHWORTH

16-17 Woodside Ind. Park

Works  Road

Letchworth

Herts

SG6 1LA

LONDON

2 - 4 Royal Lane

Yiewsley

West Drayton

Middlesex

UB7 8DL

MAIDENHEAD

Reform  Road

Maidenhead

Berkshire

SL6 8BY

MOLESEY

10 Island Farm Avenue

West Molesey

Surrey

KT8 2UZ

NEWBURY

9 Pipers Court

Berkshire  Drive

Thatcham

Berkshire

RG19 4ER

NORWICH

2b Trafalgar Street

Norwich

NR1 3HN

SUNBURY

Unit 1a

The Summit

Hanworth  Road

Sunbury on Thames

TW16 5DB

SOUTH EAST

ASHFORD

Unit 2

Bridge Road Business Centre

Bridge  Road

Ashford

Kent   TN23 1BB

FLEET

Unit 1

Redfields Ind. Estate

Church  Crookham

Fleet

Hampshire   GU13 0RD

HAYWARDS

21-25 Bridge Road

HEATH

Haywards Heath

Sussex   RH16 1UA

TONBRIDGE

Unit 30

Deacon Trading Estate

Morley Road

Tonbridge

TN9 1RA

SOUTH WEST

BARNSTAPLE

Main Road

Fremington

Barnstaple

North Devon   EX31 2NT

BOURNEMOUTH

63-65 Curzon Road

Bournemouth

Dorset

BH1 4PW

BRIDGEWATER

6 Herswell Business Park

Salmon Parade

Bridgwater

Somerset  TA6 5PY

BRISTOL

11 Eldon Way

Eldonwall Trading Estate

Bristol

BS4 3QQ

EMSWORTH

266 Main Road

Southbourne

Emsworth

PO10 8JL

ISLE OF WIGHT

Unit 8

Enterprise  Court

Ryde Business Park

Ryde

Isle of Wight   PO33 1DB

NEWTON ABBOT

Unit 2

Zealley Ind. Estate

Kingsteignton

Newton Abbot

TQ12 3TD

REDRUTH

Unit  7D

Pool Ind. Estate

Druids  Road

Redruth

Cornwall   TR15 3RH

To  contact  your  local  Service  Force  Centre  telephone 

08705  929  929

Summary of Contents for EHG 681

Page 1: ...GB Gas hob INSTRUCTION BOOKLET Please read this instruction booklet before using the appliance EHG 681 35670 2703 ...

Page 2: ...b is intended for domestic cooking only It is not designed for commercial or industrial purposes l When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose l When using the hob for a long period of time the ventilation shou...

Page 3: ...ng 5 Service and Spare Parts 6 Guarantee Conditions 6 Engineers technical data 9 Installation 10 Building In 11 Electrical connections 12 Wiring Diagram 13 Fault Finding 13 Commissioning 15 Conversion from Natural Gas to LPG 15 Description of the Hob 1 Hob Top 2 Rapid Burner 3 Semi rapid Burner 4 Auxiliary Burner 5 Control Panel 6 Control knobs 1 2 3 4 6 5 ...

Page 4: ...out you must DISCONNECT the hob from the electricity supply The hob is best cleaned whilst it is still warm as spillage can be removed more easily than if it is left to cool The Hob Top Regularly wipe over the hob top using a soft cloth well wrungoutinwarmwatertowhichalittlewashingupliquid has been added Avoid the use of the following household detergent and bleaches impregnated pads unsuitable fo...

Page 5: ... Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown Service and Spare Parts When you contact the Service Centre they will need the following information 1 Your name address and post c...

Page 6: ...liance which is improperly installed or calls to appliance outside the United Kingdom Appliances found to be in use within a commercial or similar environment plus those which are the subject of rental agreements Products of Electrolux manufacture which are not marketed by Electrolux European Guarantee If you should move to another country within Europe then your guarantee moves with you to your n...

Page 7: ... Inveralmond OWN SALES Perth PH1 3AF SHETLAND 3 4 Carlton Place Lerwick Shetland OWN SALES ZE1 0PW SHETLAND Bolts Shetland 26 North Road Lerwick OWN SALES Shetland ZE1 0PE WHALSAY Leask Electrical Harisdale Symbister Whalsay OWN SALES Shetland ZE2 9AA NORTHERNIRELAND BELFAST Owenmore House Kilwee Business Park Dunmurry Belfast BT17 0HD WALES CARDIFF Unit 4 Guardian Industrial Estate Clydesmuir Roa...

Page 8: ...West Mill Gravesend Kent DA11 0DL IPSWICH Unit 6C Elton Park Business Centre Hadleigh Road Ipswich IP2 0DD LETCHWORTH 16 17 Woodside Ind Park Works Road Letchworth Herts SG6 1LA LONDON 2 4 Royal Lane Yiewsley West Drayton Middlesex UB7 8DL MAIDENHEAD Reform Road Maidenhead Berkshire SL6 8BY MOLESEY 10 Island Farm Avenue West Molesey Surrey KT8 2UZ NEWBURY 9 Pipers Court Berkshire Drive Thatcham Be...

Page 9: ...er semi rapid Heat Input 2 0 kW 6824 BTU HR Front Left Burner rapid Heat Input 3 0 kW Natural Gas 10236 BTU HR 2 8 kW LPG 9554 BTU HR Rear Right Burner semi rapid Heat Input 2 0 kW 6824 BTU HR Front Right Burner auxiliary Heat Input 1 0 kW 3412 BTU HR Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid 32 Rapid 40 Aerationadjustmentnone NATURAL GAS 20 mbar TYPEOF GAS Characteristics LPG GAS 28...

Page 10: ...vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom shower room or garage Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm between the edge of the hob and the wall The minimum distance combustible material can be fitted above ...

Page 11: ...ow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Rectangular cut out size for hob A End of shaft with nut B Washer C Elbow It is important to install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 Gas Connection C...

Page 12: ...the fuse a 3ampASTAapproved BS 1362 fuse must be used Should the plug need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue n...

Page 13: ...ess than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal evide...

Page 14: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Page 15: ...te another burner The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar Turn off the burner supplies F F Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted The gas rate is adjusted to suit Method Ensure that...

Page 16: ...up The world s No 1 choice The Electrolux Group is the world s largest producer of powered appliances for kitchen cleaning and outdoor use More than 55 million Electrolux Group products such as refrigerators cookers washing machines vacuum cleaners chain saws and lawn mowers are sold each year to a value of approx USD 14 billion in more than 150 countries around the world ...

Reviews: