Hob
2
Hood
This is an advanced automatic function which connects
the hob to a special hood. Both the hob and the hood have
an infra-red signal communicator. The speed of the fan is
defined automatically on the basis of the mode setting and
the temperature of the hottest cooking zone on the hob.
You can also operate the fan from the hob manually.
IMPORTANT!
For most hoods, the remote system is originally
deactivated. Activate it before you use the function.
For more information refer to your hood user manual.
Operating the function automatically
The default automatic mode from the factory is H5.
You can change the automatic mode by following the
instructions below. When you activate the job the hood
will adjust the fan speed automatically. Please note the
below table is a guide, the fan speed varies depending
on the temperature measured on the cooking zones of
the cooktop which can be affected by the heat setting(s)
selected as well as the size and volume of what you are
cooking.
Automatic modes
Automatic
light
Boiling
1)
Frying
2)
Mode H0
Off
Off
Off
Mode H1
On
Off
Off
Mode H2
3)
On
Fan speed 1
Fan speed 1
Mode H3
On
Off
Fan speed 1
Mode H4
On
Fan speed 1
Fan speed 1
Mode H5
On
Fan speed 1
Fan speed 2
Mode H6
On
Fan speed 2
Fan speed 3
1. The hob detects the boiling process and activates fan
speed in accordance with automatic mode.
2. The hob detects the frying process and activates fan
speed in accordance with automatic mode.
3. This mode activates the fan and the light and does not
rely on the temperature.
Changing the automatic mode
1. Deactivate the appliance
2. Touch for 3 seconds. The display comes on and
goes off.
3. Touch for 3 seconds.
4. Touch a few times until comes on.
5. Touch of the Timer to select an automatic mode.
IMPORTANT!
To operate the hood directly on the hood panel, deactivate
the automatic mode of the function.
When you finish cooking and deactivate the hob, the hood
fan may still operate for a certain period of time. After that
time the system deactivates the fan automatically and
prevents you from accidental activation of the fan for the
next 30 seconds.