9.2
Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Multi Crown
57
9.3
Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar
4,0 kW
Gas replace‐
ment:
G30 (3+) 28-30 mbar
258 g/h
G31 (3+) 37 mbar
254 g/h
Electric supply: 220-240 V ~ 50-60 Hz
Appliance cate‐
gory:
II2H3+
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
9.4
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Multi Crown
4,0
1,4
146
9.5
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Multi Crown 3,55
1,4
095
258
254
10.
ENERGY EFFICIENCY
10.1
Product information according to EU 66/2014
Model identification
EGG3213N
Type of hob
Built-in hob
Number of gas burners
1
Energy efficiency per gas burner
(EE gas burner)
Centre middle - Multi Crown
55.3%
Energy efficiency for the gas hob
(EE gas hob)
55.3%
www.electrolux.com
16