Installation
EN
INSTALLATION
This operation must be carry on by the
service agent or similarly quali
fi
ed per-
sons in order to avoid a hazard.
Installation – Air Outlet Version
• The Hood is
fi
tted with a system that
allows the direction of the air outlet
to be adjusted.
• On installation, the Hood is set up
with the air outlet in the Top position
(
fi
g.1).
• To modify the position of the air out-
let, remove the Comfort Panel (see
paragraph on Maintenance).
• Remove the Grease Filters (see the
paragraph on Maintenance).
• Remove the pro
fi
le after unfastening
the screws that
fi
x it to the Hood
(
fi
g.2).
• Remove any Activated Charcoal
Filters (see the paragraph on Mainte-
nance).
• By removing the 6 upper screws,
the 6 rear screws and the 2 screws
on the inside of the Hood, it is pos-
sible to turn the Motor Unit with the
bracket attached so that the air out-
let points to the side (
fi
g.3).
• To direct the air outlet to one of the
various sides (
fi
g.4) unfasten from
the inside the screws that
fi
x the up-
per part containing the motor to the
rest of the Hood.
• Turn the upper part as required, to
the right or left, and then refasten
the screws removed as above from
the inside (
fi
g.5).
• Replace the pro
fi
le, using the
screws removed as above.
• Replace the
fi
lters.
• Replace the Comfort Panel.
1
2
3
4
5
Summary of Contents for EFG10750
Page 1: ...USER MANUAL EFG60750 EFG90750 EFG10750 ...
Page 2: ...We were thinking of you when we made this product ...
Page 6: ...6 electrolux CHARAKTERISTIKEN DE CHARAKTERISTIKEN Platzbedarf Min 650mm Min 650mm ...
Page 26: ...26 electrolux Caratteristiche IT CARATTERISTICHE Ingombro Min 650mm Min 650mm ...
Page 36: ...36 electrolux Characteristics EN Dimensions CHARACTERISTICS Min 650mm Min 650mm ...
Page 45: ......
Page 46: ......
Page 47: ......