48 electrolux.com.au
49
Oven dimensions
895mm
596mm
586mm
552mm
572mm
20mm
900mm
580mm minimum
Infill
panel
20mm
(see NOTE)
cupboard
door
100mm
max.
The cooking range must be connected to the
supply by a supply cord fitted with the appropriately
rated plug. This plug is to be compatible with the
socket-outlet fitted to the final sub-circuit in the
fixed wiring that is intended to supply this
cooking range.
Supply cord size required
EVEP916, EFEP915 - 4mm
2
EFEP955 - 10mm
2
CABINET CONSTRUCTION FOR BUILT IN OVEN
WIRING REQUIREMENTS
Data plate
gives information about rating
is located behind the bottom of
the oven door
•
A functional switch MUST be provided near the
appliance in an accessible position (AS/NZS 3000 -
Clause 4.7.1).
•
Wiring MUST be protected against mechanical failure
(AS/NZS 3000 - Clause 3.9).
•
This cooker requires a means of disconnection
incorporated into the fixed wiring.
•
The cooker MUST be properly earthed.
•
This range must be connected with cable of 75°C
rating minimum.
•
This product has passed the insulation resistance
test after manufacture. If the resistance reading is low
at installation, it is probably caused by moisture from
the atmosphere being absorbed by the elements
after the range has been produced. (Pass at 0.01
M
W
AS/NZS 3000 Wiring Rules Clause 8.3.6.2).
NOTE: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be removed from
between the active connections.
Rated Power Input
Model
Total kW
A1 kW
A2 kW
EFEP955
15.2
6.0
9.5
IMPORTANT!
Before you cook in your new oven it is important
that the protective oils used in the manufacture of
the product be removed.
•
Make sure that the room is well ventilated (to allow
smoke to escape).
•
Run the grill on high for 30 minutes without grill dish.
•
Then run the oven on 220°C for 1 hour.
Connecting to services and commissioning
This appliance must be installed by an authorised person,
according to all codes and regulations of:
•
Electrical supply authorities.
•
Building regulations.
•
Local government and council authorities.
•
AS/NZS5601.1 (particular attention to 6.10.1 and
figure 6.3, and clause 6.10.1.11).
•
AS/NZS 3000 (particular attention to clause 4.3.11
and clause 3.9).
Hard wiring detail
1.
Remove terminal cover plate from rear panel
of appliance.
2. Fit wires through hole in cover plate and make
connections to terminals.
3. Engage wires into plastic clip. Secure plastic clip with
two long silver screws (supplied in separate bag).
4. Replace cover plate onto rear panel.
Securing points
Plastic clips
Plastic clip
Electrical connection location
- Model EVEP916
Entry point of electrical cable
99
113
Model EFEP915