46
Control device for grease and
charcoal filters
This hood is fitted with a device that signals when it
is necessary to clean the grease filter or the
charcoal filter (if the hood is used in the
recirculation version with a charcoal filter).
On delivery, the hood is not supplied with a
charcoal filter, so the saturation indicator will be
disabled.
If the hood is to be used with a charcoal filter, the
saturation
indicator light must be enabled as follows:
Press buttons
4
and
5
simultaneously and hold
them for 3 seconds. At first only the grease filter
LED
F
will illuminate, but when the charcoal filter
LED
C
illuminates the saturation indicator will be
enabled.
To disable it: Press buttons
4
and
5
again
simultaneously and hold
them for 3 seconds, until the charcoal filter LED
C
goes out.
Grease filter LED (F)
LED
F
will start to flash when it is time to clean
the grease filter.
Cleaning will be necessary after 40 working hours.
Always comply with the maintenance instructions
for the grease filter.
Charcoal filter LED (C)
The charcoal filter LED
C
will start to flash when
the charcoal filter needs to be replaced.
This operation is necessary after approximately 160
working hours.
Resetting the saturation
indicator
After cleaning or replacing the filters, press button
1
for 3 seconds until the grease filter LED
F
or the
charcoal filter LED
C
stops flashing.
Warning!
The resetting of the saturation indicator
MUST be done in stand-by, never disconnect the
hood from the mains.
Correct ventilation
If the cooker hood is to work correctly there must
be an under pressure in the kitchen. It is important
to keep the kitchen windows closed and have a
window in an adjacent room open.