12.3 Functional testing cycle
This is an abbreviated washing programme (50 min) which allows the Service Engineer to test all the
functions that comprise a traditional washing cycle; in effect, the system simulates a normal cycle.
12.3.1 Selecting the cycle
To activate the function:
1. Press and hold down button
S1
.
2. turn the knob anti-clockwise till
Position 5
.
the LEDs LD0 and LD1 flash.
release
button
S1
.
3. Turn the knob till
Position 3
press
button
S1
.
the programme starts: the programme behaves as in a normal cycle; the PAUSE and CANCEL options
are accessible.
12.3.2 Cycle
phases
N.B.
:
At the beginning of the subsequent programme (i.e. after the test cycle), the resins are washed. The
overall duration of the test cycle is about 50 minutes.
12.4 Exiting Service and User modes
To exit these modes, turn the knob to OFF position and switch the appliance off or wait
60 seconds
:
the LEDs light up and the appliance returns to selection mode.
Phase Duration
Water fill, Turbo activation
30’’
Continuous washing, dispenser
opening
45’’
Drain dilution
Water fill
---
Continuous washing
60’’
Drain dilution
Water fill
---
Controlled washing 2600rpm,
heating at 60°C
Controlled washing 2600rpm,
maintaining at 60°C
1200’’
temperature
time