![Electrolux Diva EDW 2000 Service Manual Download Page 24](http://html.mh-extra.com/html/electrolux/diva-edw-2000/diva-edw-2000_service-manual_91966024.webp)
6.4.2. Input philosophy: select start time
(Variant B: time preselection before program selection)
1.
Switch on appliance with ON/OFF key S1.
Ä
Display LD1 with the ON/OFF key is lit.
Ä
Appliance is in the "prestart" mode.
Ä
All program keys and the "SZV" key are unlocked and can be selected
Ä
After the program has been selected you can also select possibly available
options, as far as they are permitted for the program.
2.
Actuate the start-time preselection key.
Ä
Display LD1 with the ON/OFF key is lit.
Ä
"SZV" LED is lit
Ä
set start time is flashing in the display.
Any additional key pressure causes the start time scrolling by 1 hour
1h - 2h - 3h - ... - 19h - display off (SZV=0h) - 1h - 2h - ...
3.
Indication of "SZV" is flashing in the display until an additional washing cycle will be
selected. The selected start time is not active until that time!
4.
Select desired program by pressing the corresponding key.
Ä
In addition to the LD1 display, the corresponding program LED is lit.
Ä
The LEDs of the start time key and the run time LED are lit.
Ä
The run time to be expected is flashing in the display.
Ä
All program-corresponding PAA LEDs (except the "end" LED) are lit.
5.
3 seconds after the last key actuation the set start time gets active and is running
down
Ä
In addition to the LD1 display the corresponding program LED and the "SZV" key
are lit. The start time is indicated in the display.
Start-time preselection gets active only when the door has been closed!
S1
Ein/Aus
LD1
S2
LD2
LD3
S3
S4
LD4
S5
LD5
LD6
S6
S7
LD7
S8
LD8
LD9
S9
S1
Ein/Aus
LD1
S2
LD2
S3
LD3
S4
LD4
S5
LD5
S6
LD6
S7
LD7
S8
LD8
S9
LD9
S10
LD10
LD11
LD12
S11
1.99
LD13
LD14
LD15
LD16
LD17
LD18
LD19
LD20
LD21
LD22
LD23
LD24
S10
LD10
LD11
LD12
S11
1.99
LD13
LD14
LD15
LD16
LD17
LD18
LD19
LD20
LD21
LD22
LD23
LD24
S1
On/Off
LD1
S2
LD2
LD3
S3
S4
LD4
S5
LD5
LD6
S6
S7
LD7
S8
LD8
LD9
S9
1.
LD5
1h
5.
S10
LD10
LD11
LD12
S11
LD13
LD14
LD15
LD16
LD17
LD18
LD19
LD20
LD21
LD22
LD23
LD24
LD1
start-time preselection running down.
LD1
Prog.time
1h
2.
display flashing
PAA
Delay timer
LD1
LAUFZEIT
1h
3.
display flashing
PAA
Zeitvorwahl
Prog.time
Delay timer
start time gets only active when the
program has been selected!
LD1
S5
LD5
Prog.time
124
4.
PAA
Delay timer
display flashing
aprox. 3 seconds
per key pressure
+ 1 hour
display flashing
Prog.time
Delay timer
2h
3h
19h
124
display flashing
Prog.time
Delay timer
display flashing
Prog.time
Delay timer
display flashing
Prog.time
Delay timer