![Electrolux ComfortLift ESF8735ROX Service Manual Download Page 17](http://html.mh-extra.com/html/electrolux/comfortlift-esf8735rox/comfortlift-esf8735rox_service-manual_91930017.webp)
3.10. Pressure sensor
Details
1-
Pressure sensor with radial
sealing
2-
Pressure sensor snap:
robust snap from bottom
ribs in sump to limit rotation
half round rib to limit move
upward
Frequency output (0-5V Signal),
Range: 0-300mm
Connection: 3 connectors RAST 2.5mm
Pressure
mmWc/PA
Frequency
Tolerance 20⁰C
Tolerance 70⁰C
-
44.3
+ / - 3mmWC / 1%
+ / - 5mmWC / 1.7%
75
42.16
+ / - 3mmWC / 1%
+ / - 5mmWC / 1.7%
150
40.0
+ / - 6mmWC / 2%
+ / - 8mmWC / 2.7%
225
37.77
+ / - 9mmWC / 3%
+ / - 11mmWC / 3.7%
1
2
17/60