These warnings are provided in the interests of safety. Ensure that you understand them all before
installing or using this appliance. Your safety is of paramount importance. If you are unsure about
any of the meanings  of these warnings contact the Customer Care Department.

Installation

Any installation work must be undertaken
by a qualified electrician or a competent
person.

This hood must be installed in accordance
with the installation instructions and all
measurements must be adhered to.

If the cooker hood is installed for use above
a gas appliance then the provision for
ventilation must be in accordance with the
Gas Safety Codes of Practice BS.6172,
BS.5440 and BS.6891 (Natural Gas) and
BS.5482 (LP Gas) 1994, the Gas Safety
(Installation & Use) Regulations, the
Building Regulations issued by the
Department of the Environment, the Building
Standards (Scotland) (Consolidated)
Regulations issued by the Scottish
Development Department.

The fan motor of this cooker hood
incorporates a cut-out device which will
operate if the cooker hood is installed below
the minimum height recommended under the
section ‘Clearance Height’, or if the motor
becomes overheated. If the cut-out device is
activated, switch off the fan motor and allow
the cooker hood to cool. The cut-out device
will reset itself when the fan motor has
cooled significantly.

It is dangerous to alter the specifications or
modify this product in any way.

When installed between adjoining wall
cabinets the wall cabinets must not overhang
the hob.

If the room where the cooker hood is to be
used contains a fuel burning appliance such
as a central heating boiler then its flue must
be of the room sealed or balanced flue type.

If other types of flue or appliances are fitted
ensure that there is an adequate supply of air
to the room.

The ducting system for this appliance must
not be connected to any existing ventilation
system which is being used for any other
purpose.

Do not install above a cooker with a high-
level grill.

Child Safety

This appliance is designed to be operated by
adults. Children should not be allowed to
tamper with the appliance.

During Use

This product is for domestic use only.

Never leave frying pans unattended during
use as overheated fats and oils might catch
fire.

Never do flambé cooking under this cooker
hood.

Do not leave naked flames under the cooker
hood.

Maintenance and Service

This appliance can be a hazard if the grease
filters and charcoal filters are not cleaned
and replaced as recommended.

Under no circumstances should you attempt
to repair the appliance yourself. Repairs
carried out by inexperienced persons may
cause injury or more serious malfunction.
Refer to your local Electrolux Service Force
Centre. Always insist on genuine spare parts.

IMPORTANT SAFETY INFORMATION

Summary of Contents for CH60

Page 1: ...INSTRUCTION BOOK CHIMNEY HOOD CH60 and CH90 cod 4329619 03 010910 ...

Page 2: ...nformation Your Appliance Operating Instructions Cooker Hood Controls To Operate Recirculation Extraction Maintenance and Cleaning External Cleaning Metal Grease Filters Charcoal Filters To Remove Replace the Charcoal Filters Changing the Light Bulb Something Not Working Service and Spare Parts Guarantee Conditions For the Installer Technical Information Electrical Connection Electrical Requiremen...

Page 3: ...tself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabinets the wall cabinets must not overhang the hob If the room where the cooker hood is to be used contains a fuel burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type If ...

Page 4: ...ches located to the right on the underside of the hood immediately in front of the metal grease filters Worktop Lighting The switch L marked with the lamp symbol operates the worktop lighting L 0 OFF 1 ON Fan Control The switch M marked with the fan symbol and the switch V marked 1 2 3 operates the fan M 0 OFF 1 ON V 1 Low 2 Normal 3 Boost YOUR APPLIANCE OPERATING INSTRUCTIONS ...

Page 5: ...k Extraction In the extraction mode the contaminated air enters the cooker hood passing through the grease filters and is passed out through the ducting into the atmosphere To obtain the best performance when cooking it is advisable to switch the cooker hood on for a few minutes before you start cooking and leave it running for about 15 minutes after finishing When used in the ducting mode the cha...

Page 6: ...grease and dust during cooking to help keep the cooker hood clean inside and should be cleaned approximately once every month or more often if the hood is used for more than 3 hours a day Remove Replace the metal grease filters 1 Press against the metal catch to release the spring catch as illustrated in Fig 1 2 Drop the front edge of the cassette down as illustrated opposite and lift the back edg...

Page 7: ...ion as illustrated in Fig 2 This appliance can be a possible fire hazard if the grease and charcoal filters are not cleaned and replaced as recommended Changing the Light Bulb 1 First remove the metal grease filters 2 The light bulbs can be reached from inside the canopy 3 Rotate the light bulb anticlockwise to unscrew 4 To replace the light bulb insert a replacement into the holder then rotate th...

Page 8: ...ntry of fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been tripped Turn off the hob and then wait for the device to reset In guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a...

Page 9: ...s incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are the subject of rental agreements Products of Electrolux manufacture which are not marked by Electrolux This guarantee is in addition to your statutory and legal rights ELECTROLUX EUROPEAN GUARANTEE If ...

Page 10: ... the National Inspection Council for Electrical Installation Contracting NICEIC Electrical Connection Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker Note CE Marking certifies that this appliance complies with the requirements laid down in EEC directive 89 336 Electromagnetic compatibility and subsequent modificat...

Page 11: ...urface over a cooking area and can be used in the extraction ducted to the outside or recirculation mode The installation work must be undertaken by a qualified and competent person The manufacturer disclaims any responsibility for damage due to incorrect installation of the cooker hood or if the hood is not installed in compliance with relevant regulations controlling this type of installation Un...

Page 12: ...binet and the worktop must be 450mmm 17 ins a gap of 50mm 2 ins must be maintained either side of the hob This cooker hood must not be installed above a cooking appliance with a high level grill Fitting the Wall Brackets 1 Draw a vertical line on the wall from the centre of the cooking appliance up to the ceiling using a spirit level and marker pen This is to ensure the correct vertical alignment ...

Page 13: ...supplied as illustrated in Fig 4 5 Splashback Optional When the splashback is to be fitted the distance between the cooker hood and the cooking appliance will be determined by the height of the splashback B as illustrated in Fig 4 Position the splashback on the worktop ensuring the worktop is level first as illustrated in Fig 4 then holding the splashback against the wall mark the position of the ...

Page 14: ...ting The hood is more effective when used in the extraction mode ducted to the outside Venting kits may be purchased through your retailer or DIY store and must be ducted to an outside vent of 125mm 5 The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102 B1 When the cooker hood is ducted to the outside the charcoal filters must b...

Page 15: ...duced by 1 metre for each 90o bend installed in the ducting run If the distance is greater than 3 metres the efficency of the hood could be impaired The diameter of the spigot on top of the hood is 150mm 6ins A ducting adapter from 150mm 6ins to 120mm 5ins is supplied together with a 120mm to 125mm ducting collar If the room where the cooker hood is to be used contains a fuel burning appliance suc...

Page 16: ...on S first Expand the chimney slightly to allow it to be fitted over the brackets 2 and then secure the chimney stack to brackets using the four self tapping screws provided as illustrated in Fig 7 3 Fit the lower chimney section I by expanding the chimney slightly to allow it to be fitted over the brackets 1 and the upper chimney section and bracket 2 as illustrated in Fig 7 4 Secure the bottom o...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...55 77 High Street Slough BERKSHIRE SL1 1DZ Electrolux Household Appliances Limited 2001 ...

Reviews: