487 03 29 91
30.1
30. Motors
30
Service
manual
Description
(230V 50 Hz; 400-415V 50 Hz and 440V 60 Hz)
The motor is mounted under the drum and drives the drum directly on its output shaft. To
reduce motor noise and vibration the entire drum unit has rubber dampers. On flexibly-
mounted models this damping is provided by either eight or ten rubber straps, while the
drum models this of R- models is mounted on two relatively rigid rubber bushings.
Electrical connection is to block X1 in the control unit.
The extractor connection is to block X1 in the control unit.
The extractors are prepared for switching between star connection (400 - 415V) and
delta connection (230V). Switchover is performed by changing a cable set between relay
and motor. For 440V 60 Hz, cable set A is used.
Cable set A = star connection
When switching over the auxiliary transformer the strap on the transformer connection
block should be moved to the desired voltage.
Please note!
When the extractor connection type is being switched over,
the auxilliary transformer must also be switched accordingly.
1
1
B
A
Summary of Contents for C240
Page 1: ...Service Manual C240 C260 C240R C260R C290R 487 03 29 91 EN 08 28 ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 19: ...487 03 29 91 12 7 12 Functions sequences 12 Service manual 4 S1 6 S1 7 S4 2 Y1 H1 SW2 R2 R1 ...
Page 23: ...487 03 29 91 12 11 12 Functions sequences 12 Service manual 6 S2 2 SW3 R1 R2 ...
Page 27: ...487 03 29 91 12 15 12 Functions sequences 12 Service manual F E D C B A R1 R2 ...
Page 28: ......
Page 36: ......
Page 40: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...