12. Functions sequences
12
Service
manual
487 03 29 91
12.12
Faults and corrective action required
Faults indecated by flashing yellow light
Fault
Possible
cause
Action
1. The extractor will not start. Yellow
Reed element ring in the deck is
Disconnect main power supply to
light flashing.
defective
extractor. Check that the two
connentions of the Reed ring to the
circuit
board
for
automatic
functions
are
OK.
If
they
are
sound,
replace
the
Reed
ring.
2. The extractor has switched to
The Reed in the deck or the micro-
Disconnect main power supply to
braking during extraction. The
switch SW1 has developed a defect
extractor. Check that the two connections
extractor will not restart.
during extraction.
of the Reed ring to the circuit board for
automatic
functions
are
OK.
If
they
are
sound,
replace
the
Reed
ring.
Check
that
the
microswitch
SW1
is
OK.
3. The yellow light starts flashing upon
The Hall element of the is
Disconnect main power supply to
braking. The brake switches off and
defective.
extractor. Check the 3-pole connection
the extractor remains locked.
to the circuit board. If this is sound,
replace
the
motor.
4. No signal comes from the machine´s
• The microswicth of the rotation
Disconnect main power supply to
mechanical rotation guard upon
guard has stuck in its rest position.
extractor. Remove cover of automatic
braking (at the point where the drum
control unit. Open extractor lid manually
begins to rotate anticlockwise).
• The motor brake pads are worn
by pressing the yoke of the traction
magnet
upwards.
The drum rotates anticlockwise for
• The microswitch of the rotation
approx. 1 1/2 minutes and then
guard has moved from its position.
Connect a multimeter between
braking switches off and the yellow
connections 502 AC and 503 AC (S1:2-7)
light starts to flash (time varies
Turn the drum anticlockwise by
according to machine type, load and
hand. If the rotation guard is sound the
frequency).
meter
should
react.
The extractor´s lid remains locked.
If the meter does not react - check the
contacts
in
the
4-pole
connection
block
X8/X9)
and
the
3-pole
connection
block
X10/X11.
If
contact
is
correct
from
X10
to
S1
replace
the
motor.
5. The signal from the machine´s
The rotation guard microswitch has
Disconnect main power supply to
mechanical rotation guard is
burnt out in the active position.
extractor. Remove cover of control unit
constantly active. Braking switches
Open extractor lid manually by pressing
off immediately. The extractor lid
the yoke of the traction magnet
remains
locked.
upwards.
The yellow light flashing after
Connect a multimeter between
approx. 1 1/2 minutes.
connections 502 AC and 503 AC (S1:2-7)
If
the
rotation
guard
is
sound
the
meter
should
react.
if
the
meter
does
not
react
-
check
wires
and
connection
blocks
X8/X9
and
X10/X11
for
short
circuits.
If
there
is
no
short
circuit
in
the
control
unit,
the
microswitch
in
the
motor is faulty-
replace
the
motor.
Summary of Contents for C240
Page 1: ...Service Manual C240 C260 C240R C260R C290R 487 03 29 91 EN 08 28 ...
Page 2: ......
Page 4: ......
Page 8: ......
Page 10: ......
Page 12: ......
Page 19: ...487 03 29 91 12 7 12 Functions sequences 12 Service manual 4 S1 6 S1 7 S4 2 Y1 H1 SW2 R2 R1 ...
Page 23: ...487 03 29 91 12 11 12 Functions sequences 12 Service manual 6 S2 2 SW3 R1 R2 ...
Page 27: ...487 03 29 91 12 15 12 Functions sequences 12 Service manual F E D C B A R1 R2 ...
Page 28: ......
Page 36: ......
Page 40: ...www electrolux com laundrysystems Share more of our thinking at www electrolux com ...