Page 5 RESI219
ELECTROLUX ELECTRONICS
The top of the range cabinets will be fitted with an Electrolux Electronic control. This consists of a
Control Board, Relay Board, User Interface (Control Display) and Two Sensors. Functionally this
replaces the thermostat and defrost timer and provides some extra features.
DESCRIPTION OF CONTROL AND OPERATION
COMPONENTS
The electronic control consists of the following parts-
Control Board located in the machine compartment.
Relay Board located in the top right hand side of the food compartment control housing.
User Interface (Control Display) recessed into the front of the freezer compartment door
Two sensors, one in the fresh food compartment and one in the freezer compartment (wired into
the cabinet harness)
The Control Board houses the transformer, 3 Triacs (compressor, fan and defrost heater) and input
circuitry to monitor when the door/defrost heater is open/on and for how long. A processor controls the
timing on some of the functions such as the door alarm and also communication between the Control
Board and User Interface (Control Display).
The Relay Board houses the transformer and 3 relays (water valve, block ice soleniod and auger motor).
This is to facilitate the use of 5 and 12 volt wiring only through the freezer door hinge to the user
interface (Control Display) in the freezer door.
The User Interface (Control Display) consists of a LCD Display with white backlighting, 6 LED down
lights and nine push buttons. A processor controls the LCD segments and also communication between
the User Interface (Control Display) and Control Board.
The sensors are negative temperature coefficient silicon devices encapsulated in a PVC tube sealed with
epoxy resin. Typical resistance at 25°C is 5000 ohms, at 0°C is 16325 ohms and at -25°C is 65200 ohms.
OPERATIONAL SUMMARY
The system operates under software control from direct current inputs from sensors located in the freezer
and fresh food compartments.
The fresh food compartment is supplied with cold air from the freezer compartment by a fan located in
the freezer compartment. The flow of air to the fresh food compartment is controlled by a motorised
baffle that is either fully open or fully closed. This baffle takes 12 seconds to open or close.The baffle is
located in the rear control housing at the air outlet of the freezer.
When the freezer compartment is too warm, the compressor is turned on (by the freezer sensor signal)
together with the fan. The fan draws refrigerated air (dry, sub-zero air) from a finned evaporator coil.
When the fresh food compartment is too warm, the baffle in the rear control housing is opened.
Depending on which cycle the refrigerator is in (On or Off) depends on which of the following will occur
•
If the freezer fan and compressor are on, the cold air will flow from the freezer into the food
compartment.
Summary of Contents for B Series
Page 4: ...Page 4 RESI219 ...
Page 8: ...Page 8 RESI219 ...
Page 9: ...Page 9 RESI219 ...
Page 10: ...Page 10 RESI219 ...
Page 11: ...Page 11 RESI219 ...
Page 12: ...Page 12 RESI219 ...
Page 13: ...Page 13 RESI219 ...
Page 14: ...Page 14 RESI219 ...
Page 15: ...Page 15 RESI219 ...
Page 16: ...Page 16 RESI219 ...
Page 17: ...Page 17 RESI219 ...
Page 18: ...Page 18 RESI219 ...
Page 19: ...Page 19 RESI219 ...
Page 20: ...Page 20 RESI219 ...
Page 27: ...Page 27 RESI219 OPERATING CYCLE ILLUSTRATIONS MECHANICAL ...
Page 28: ...Page 28 RESI219 ...
Page 29: ...Page 29 RESI219 OPERATING CYCLE ILLUSTRATIONS ELECTRICAL ...
Page 30: ...Page 30 RESI219 ...
Page 31: ...Page 31 RESI219 ...
Page 37: ...Page 37 RESI219 ...
Page 38: ...Page 38 RESI219 DOOR GASKET REMOVAL ...
Page 39: ...Page 39 RESI219 DOOR GASKET REMOVAL ...
Page 40: ...Page 40 RESI219 ...
Page 41: ...Page 41 RESI219 Gasket Profiles DOOR GASKET REPLACEMENT ...
Page 42: ...Page 42 RESI219 ...
Page 43: ...Page 43 RESI219 ...
Page 44: ...Page 44 RESI219 ...
Page 46: ...Page 46 RESI219 REMOVAL OF THE FREEZER FAN D T T HEATER HARNESS CONNECTIONS ...
Page 48: ...Page 48 RESI219 ...
Page 49: ...Page 49 RESI219 ...
Page 50: ...Page 50 RESI219 ...
Page 51: ...Page 51 RESI219 ...
Page 52: ...Page 52 RESI219 REMOVAL OF THE FREEZER LIGHT GLOBES ...
Page 53: ...Page 53 RESI219 ACCESS TO THE CONTROL BOARD COMPRESSOR CONDENSER FAN CONDENSER WATER VALVES ...
Page 55: ...Page 55 RESI219 MODELS WSE6070PB 06 AIR FLOW R757 WSE6070SB 06 WSE6070WB 06 ...
Page 56: ...Page 56 RESI219 MODELS WSE6070PB 06 AIR FLOW R1051 WSE6070SB 06 WSE6070WB 06 ...