25
N.B. The default parameters (DEF.) may vary for different
appliance models.
D.6 LIST OF USER PARAMETERS
SYMBOL
RANGE
DEF.
MIN
Internal clock: Minutes
0..59
0
HOUR
Internal clock: Hours
0..23
0
DAY
Internal clock: Days
1..31
1
MON
Internal clock: Month
1..12
1
YEAR
Internal clock: Year
0..99
0
SrF
Indicates the cell temperature set point for the positive holding cycle and the conservation
phase after positive chilling
-
25..10°C/F
3
SFF
Indicates the cell temperature set point for the negative holding cycle and the conservation
phase after negative chilling
-
25..10°C/F
-25
LAC
Temperature difference from absolute temperature/conservation set point, below which a
low temperature alarm is generated
-50..125°C/F
5
HAC
Temperature difference from absolute temperature/conservation set point, below which a
high temperature alarm is generated
-50..125°C/F
5
CdiF
Indicates whether the LAC and HAC temperature limits are expressed as differential (d) or
absolute (A).
A/d
D
SLd
Indicates duration of sanitation cycle
0..240
10
bCCy
Buzzer mode to indicate to indicate correct conclusion of a chilling cycle
Nob
bbl
'nob' = buzzer off
bbl
'bbl' = buzzer on for 30 seconds
lbl
"llb" = buzzer on until any key is pressed
bFCy
Buzzer mode to indicate HACCP alarms
bbl
bAll
Buzzer mode to indicate a generic alarm
lbl
CCEt
“CUSTOM” standards: END OF POSITIVE CHILLING TEMPERATURE
0..CbSt°C/F
10
CCtI
“CUSTOM” standards: END OF POSITIVE CHILLING TIME
0..360 min
110
CFEt
“CUSTOM” standards: END OF NEGATIVE CHILLING TEMPERATURE
-35..CbSt°C/
-18
CFtI
“CUSTOM” standards: END OF NEGATIVE CHILLING TIME
0..360°C/F
270
CbSt
“CUSTOM” standards: START OF CHILLING TIME
0..127°C/F
63
EICE
The utility enables the utility of cycles ICE P1 and P2 instead of the custom programmes
Y/N
N
tPrA
Indicates printing cycle during a chilling cycle. If set to 0, only the temperatures at the
beginning and end of the cycle are printed.
1..255 min
5
tPrC
Indicates the printing interval in conservation /holding. If set to 0, no value is printed.
1..255 min
30
PrnL
Configuration of printout language:
It = Italian, Gb = English, dE = German, fr = French, Es = Spanish, Se = Swedish
It/Gb/dE/fr/
Es/Se
Gb
Adr
Network address
01-FF
1
E485
Type of connection
Prn/PC
Prn
"Prn" = Printer;
"PC" = Personal Computer;
nOr
Indicates applicable standards, whether “NF”, “UK” or “CUSTOM”
nF, Uk, CuSt
Uk
REL
Software version
-
-