13
ENGLISH
F
INSTALLATION AND ASSEMBLY
F1
Customer responsibilities
The Customer must provide for the following:
-
Install a disconnecting switch with a capacity at
least equal to that given in the technical data table,
a 30mA residual current circuit breaker and an
overcurrent device (magnetothermal cut-out with
manual reset or fuse) between the appliance and
the mains power outlet. The chosen device must be
lockable in the open position in case of mainte-
nance.
-
install an adequate electrical power supply ahead
of the appliance, according to the equipment’s tech-
nical specifications (Table 1 and D2 “Characteris-
tics of power supply”);
-
the equipotential connection of the workplace elec-
trical system to the metal structure of the appliance
by means of a copper cable of adequate section
(see position “EQ” in par. F6.2 “Installation dia-
grams”);
-
Adducting for the electrical connection between the
workplace electric panel and the equipment;
-
the water supply and drain connections and other
connections as indicated in Table 1 and par. F6
“Plumbing connections”;
F2
Characteristics of the place of appliance
installation
The appliance is designed for installation in profes-
sional and not domestic-type kitchens. Water collec-
tion traps/metal grates must be arranged in the floor at
the appliance discharges (see pargraph F6.2 “Installa-
tion diagrams”), possibly replaceable with a single
water trap sized for a flow rate of at least 3 l/s.
F3
Appliance space limits
A suitable space must be left around the appliance (for
operations, maintenance, etc.).
The passages enabling personnel to operate on the
appliance must be at least 50 cm wide, except at the
rear of the appliance.
The size must be increased in case of use and/or
transfer of other equipment and/or means or if exit
routes are necessary inside the workplace.
F4
Positioning
The appliance must be taken to the place of installa-
tion and the packing base removed only when being
installed.
Arranging the appliance:
•
Wear protective gloves and unpack the appliance
(Figure 5).
Figure 5 Unpacking
•
Lift equipment with a lift truck, inserting the forks as
indicated below, remove the base and position the
appliance where it is to be installed (Figure 6).
•
Remove the wooden spacers "A" on the appliance
base by undoing the four M8 screws (see Figure 7).
IMPORTANT!
Appliance installation operations must
only be carried out by specialized Techni-
cians provided with all the appropriate
personal protection equipment (safety
shoes, gloves, glasses, overalls, etc.),
tools, utensils and ancillary means.
Figure 6 Appliance positioning
Figure 7 Removal of wooden spacers
3
2
1
3
2
1
3
2
1
3
2
1
3
2
1
M
8
A
A