30
5.1.6.5 MINIMUM FLAME SCREW REPLACEMENT (hob)
•
Unscrew minimum flame screw “M” from the cock and
replace it with one suitable for the type of gas (screw down
fully) (Table B, fig.2B)
5.1.6.6 PILOT FLAME ADJUSTMENT (hob without
thermocouple)
Pilot flame height is factory-set; if necessary, it can be adjusted
by proceeding as follows:
•
Remove the control panel and locate the cock
corresponding to the flame to be adjusted (“B1” front ring,
“B2” rear);
•
Turn the screw to increase or decrease the height of the
pilot flame.
•
Refit the control panel after completing the operation
A
B2
B1
5.1.6.7 PILOT FLAME ADJUSTMENT
(hob with
thermocouple)
•
Remove the control panel and turn screw “C” to increase or
decrease the height of the pilot flame.
•
Refit the control panel after completing the operation
A
C
6. BEFORE COMPLETING THE
INSTALLATION OPERATIONS
Use soapy water to check all connections for gas leaks. DO
NOT use a naked flame to check for gas leaks. Light all the
burners separately and also together, to check correct
operation of the gas valves, rings and lighting. Adjust the
flame regulator to the lowest setting for each burner, separately
and together; after completing the operations, the installer
must instruct the user on the correct method of use. If the
appliance does not work properly after carrying out all the
checks, contact the local after-sales service centre.