![Electrolux 10 GN 1/1 User Manual Download Page 29](http://html.mh-extra.com/html/electrolux/10-gn-1-1/10-gn-1-1_user-manual_17720029.webp)
29
Anom-
aly
Type of
anomaly
Description
Possible causes
Actions
EbOL
Stops
cycle/
preheating
Boiler thermocouple
failure
• Connector failure;
• TC sensor failure;
• PCB failure.
The oven can continue to work without preheat-
ing (check the cooking results).
• Inform Service about the failure.
EbYP
Warning
Steam exhaust tem-
perature sensor failure.
• Connector failure;
• TC sensor failure;
• PCB failure.
The oven can continue to work, it is possible that
water consumption increases.
Call Service.
ECEd
Stops
cycle
Bottom cavity thermo-
couple failure
• Connector failure;
• TC sensor failure;
• PCB failure.
The oven can continue to work only with 100
℃
steam cycle.
Call Service.
ECEu
Stops
cycle
Upper cavity thermo-
couple failure
• Connector failure;
• TC sensor failure;
• PCB failure.
The oven can continue to work only with 100
℃
steam cycle.
Call Service.
EH2O
Stops oven
Water measured
inconsistent with
valves state
• Water supply valve
closed or partly closed;
• Temporary lack of water
supply pressure;
• Flow meter failure;
• Water system issue.
The oven can continue to work (check the cook-
ing results).
• Check if the water supply valve is open;
• Check the water pressure is > 1,5 bar;
• If the problem, persists call Service.
ELMb
Stops
cooking
with steam
over 100
℃
Detected a problem
with the oxygen sensor
• Lambda probe failure.
It is possible to continue using the oven in Steam
under 100
℃
• Cooking results in Steam mode may be differ-
ent from usual.
• Call Service in case cooking results are
persistently unsatisfactory.
EntC
Stops oven
component compart-
ment NTC failure
(NTC1)
• Connector failure;
• TC sensor failure;
• PCB failure.
Electronic board temperature sensor damaged.
• Cooking impossible.
• Call Service.
Eotd
Warning
High temperature on
water drain
Possible lack of water in the
drain system.
• Check that the oven has water supply;
• Pour some water on the bottom cavity filter;
• If the problem persists call Service.
Eprb
Stops oven
in Food
probe
mode
Core probe failure
• Food probe misuse (for
example, wire pulled or
squeezed);
• Connector failure;
• Probe failure;
• PCB failure.
It is possible to run cycles based on time (without
food probe);
• If available, use the accessory USB food
probe;
• Call service to restore food probe mode
functionality.
Ertc
Warning
Problem with internal
clock
Issue with software or hard-
ware (for example battery
clock exhausted).
It is possible that some functionality do not work
(for example HCCP).
• Call Service.
ESCH
Stops oven
Component compart-
ment overtemperature
• Filter is dirty;
• Too high room
temperature.
• Check room temperature considering the
oven needs fresh air to cool electronic
compartment;
• Clean the filter;
• Allow oven to cool before cooking;
• Call Service if the problem reoccurs.
EStd
Warning
Water drain NTC
failure
• Connector failure
• NTC sensor failure
• PCB failure
The oven continue to work.
• Call Service to fix the issue.