![Electrolux Professional WB6-20 Installation Manual Download Page 56](http://html.mh-extra.com/html/electrolux-professional/wb6-20/wb6-20_installation-manual_2385656056.webp)
56
Installation manual
The gas exchanger is adjusted at the plant to be suitable for the kind of gas specified on the order. If you have to sup-
ply your machine with gas in a family different from the gas for which your machine was adjusted, proceed as follows.
Important
Testing pressures
According to the EN 437 standard, the values of the testing pressures mentioned in our various documents are
values for static pressure taken at the gas inlet connection of the machine ; the heating of the machine being on.
22.6.1 Changing to a gas in the same family (type H or L)
Change the 3 injectors with joints (see tables of correspondences).
22.6.2 Changing to a gas in a different family (from type H or L to butane or propane)
• Change the 3 injectors with joints (see tables of correspondences).
• Unscrews the fixing screws (V) and remove the adjusting head (J) as well as its cork (T), keep these parts in case
a change would by necessary.
• Replace it by the cork (L) and the plate (P).
• Screw the two screws and block.
22.6.3 Changing a gas from one family to another (from butane or propane to type H or L)
• Change the 3 injectors with joints (see tables of correspondences)
• Unscrews the fixing screws (V) and remove the plate (P) as well as the cork (L), keep these parts in case a change
would by necessary.
• Set the cork (T) and the adjustment head (J).
• Screw the two screws and block.
Important
Adjustments should be made by qualified personnel only.
22.7 Adjustment and checking of the outlet pressure
The gas outlet pressure of the electrovalve is adjusted at the factory. If you have to make another adjustment, pro-
ceed as follows.
Summary of Contents for WB6-20
Page 1: ...Installation manual Washer extractors WB6 20 WB6 27 WB6 35 Original instructions 05201148 EN ...
Page 2: ......
Page 25: ...Installation manual 25 Back view Right view Drain connection Top view ...
Page 47: ...Installation manual 47 No Barrier washer Barrier washer ...
Page 49: ...Installation manual 49 Front view Side view Top view Gas exchanger with draught accelerator ...
Page 62: ...62 Installation manual ...
Page 71: ......
Page 72: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...