Calibration of the scale (weight function)
Calibration of the scale (weight function)
Zero adjustment of the scale (weight function)
The scale itself is calibrated from factory and no adjustment should be
necessary unless some scale parts need to be changed. However a zero
adjustment needs to be done as the total weight of the machine needs to
be programmed into the scale.
Be sure that the water and drain hoses are in place and properly mounted.
Be sure that all panels are mounted and the cover over the power connec-
tion is placed on top of the machine.
• Enter the ”service mode” as in level calibration.
• In ”service mode” go to ”scale adjustment”
• Press ”Select”
• Go down to ”Zero calibration”
• Press ”Select”
• Press ”Select” (Be sure that there are no extra weight on the machine.
And don´t lean on the machine).
• When display text ”Reset scale from calibration…” appears,
press ”Select”
• Go down to ”Exit”
• Press ”Select”
• Go back to main menu.
The zero adjustment is now done and the weight of the emty machine
should now be red on the display as 0.0 kg (a difference of ±0.1 kg is al-
lowed). If an other value is shown in the display , the zero adjustment has
to be done again from the start.