51
Procedure for use
Put the calibration
weight in the drum.
Press SELECT.
If you want to use the
”Calibrate zero” function
now:
Press SELECT.
Calibration weight
A weight of between 40 kg and 400 kg should be
used as a calibration weight.
The higher the weight (within these limits), the better
the weighing accuracy of the machine.
Remove the calibration
weight.
Press SELECT.
Use the numeric keys
to enter the calibration
weight in hg (1 hg = 100
grams).
Press SELECT.
For machines with weighing equipment installed only!
4785
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
FILL DRUM WITH CALIBRATION WEIGHT
ENTER WEIGHT IN HG AND
PRESS SELECT
SELECT
SELECT
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
DONE! PRESS SELECT
SELECT
SELECT
3588
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
REMOVE WEIGHT AND PRESS SELECT
SELECT
SELECT
3588
SCALE ADJUSTMENTS
CALIBRATE THE SCALE
PRESS SELECT FOR ZERO CALIBRATION
SELECT
SELECT
3588
Summary of Contents for Wascator FOM71 CLS
Page 1: ...Operating manual Wascator FOM71 CLS 438 9094 01 EN 2020 01 16 Original instructions ...