26
H
ELECTRICAL INSTALLATION
H.1
Gas, electricity, water and other
connections (if present, depending on
the appliance and/or model)
• Any installation work or maintenance to the supply system
(gas, electricity, water and/or steam, if present) must only
be carried out by the utility company or an authorised
installation technician.
• Refer to the appliance dataplate for the product code.
• See the installation diagram for the type and position of
appliance connections.
H.2
Mains connection
WARNING
Work on the electrical systems
must only be carried out by
specialised personnel.
Before connecting, make sure that:
• the mains voltage and frequency match those indicated on
the appliance data plate.
• the electrical connections must comply with the local
authority regulations in force in the country of use.
• a differential thermal-magnetic switch suitable for the input
specified on the data plate, with contact gap enabling
complete disconnection in category III overvoltage condi-
tions and complying with the regulations in force, is installed
between the power cable and the electric line.
For the correct size of the switch, refer to the absorbed
current specified on the appliance data plate.
• In case of marine installations: the fluctuation of the voltage
must not be higher than ±6 %.
It must be possible to block the system in an open position for
maintenance purposes, to prevent it from being switched on
unintentionally.
IMPORTANT
The manufacturer declines any liability if the safety
regulations are not respected.
Each appliance has a specific wiring diagram. This contains
the technical specifications (electrical rating, voltage, amper-
age etc.).
The mains supply is connected via cable installed during
assembly, which protrudes approximately 1,5 m out of the floor
or wall.
The Installation and Connection Diagram (F
) shows the position of the main terminal board.
To get access to the connection terminal inside the appliance,
follow the instructions in F.3
Accessing the appliance’s internal
H.3
Power cable
Unless otherwise specified, our appliances are not equipped
with a power cable. The installer must use a flexible cable
having characteristics not lower than the H05RN-F rubber
insulated type.
WARNING
If the power cable is damaged, it
must be replaced by the Cus-
tomer Care Service or in any
case by specialised personnel,
in order to prevent any risk.
Connect the AC power cord to the main terminal board using a
cable relief, in accordance with the electrical wiring diagram.
H.4
Potential equalisation
The appliance must be connected to a point
indicated on a potential equalisation system with a
minimum conductor cross section of 10 mm².
When installing multiple appliances, connect them all together
through potential equalisation.
1. 6 mm lug
2. M6 nut
3. M6 threaded bolt
4. M6 spring washer
5. M6 washers
NOTE!
You need a potential-free contact to indicate on an
external circuit chart, whether the appliance is
switched on or not. The terminals are labelled 21
and 22.
I
OPERATING INSTRUCTIONS
I.1
Use
The appliance is intended for industrial use by trained
personnel.
This appliance must only be used for its expressly designed
purpose, i.e. for directly cooking food (stews, soups, meat, fish
and vegetables).
Any other use is considered improper.
Do not use the appliance to warm up or indirectly cook food in
pots, casserole dishes or pans, etc.
IMPORTANT
Never use this machine for frying.
• The cooking pan is seamlessly integrated into the
machine's cover.
• For units with a width of 800 mm, the cooking pan has 2
heat zones which are heated independently.
• At the front of the pan is a 2″ drain hole, through which food
is drained into a collection container inside the appliance.
You must use the supplied plug to close the drain hole.
• A safety thermostat prevents unacceptably high temper-
atures from being reached.
WARNING
If the pan is empty, do not switch
on or carry on heating.
1
2
3
4
5
Summary of Contents for thermaline 1/1 GN