Insert the cable in the hole (A) on the top of the drying cabinet.
A
fig.W01244
Connect the ground cable and the other cables as illustrated.
230V 1N ~
Ext. Fan
230V 50Hz
Pos. 17
Pos. 5
8
2
1
L1
N
PE
400V 3N ~
Ext. Fan
230V 50Hz
Pos.5
Red/L3
12
11
10
9
8
2
1
Brown/L2
Black/L1
Blue/N
L1
L2
L3
N
PE
Reinstall the front panel when you are done.