Installation manual
29
7 Electrical connection
The electrical installation may only be performed by qualified personnel.
Electrical connection of the cabinet must be done in accordance with electrical safety regulations.
Make sure that the connection current is in line with the data on the identification plate and that the mains cable
is grounded properly according to the applicable standard. We recommend that the mains cable be equipped
with a ground fault interrupter.
The manufacturer disclaims all liability if the electrical connection is not done in the manner prescribed in this
manual.
The drying cabinet must be connected to an all-pole circuit breaker.
Heating options
Mains voltage
Hz
Heat output
kW
Total output
kW
Recommended fuse
A
Electrically heated
400V 3N ~
50
9.0
9.1
16 slow-blow
7.1
Network Functions
Note!
Can only be used on premium products.
This product can be connected to ELS VISION or to an external payment system.
fig.W01529
Connecting to ELS Vision
Connect the network cables GND, RX, TX, 24V to the terminal block as illustrated.
Connect the neutral position switch to terminal block positions 1 and 2, as illustrated.
Activate the connection to ELS Vision as follows:
Press and hold the Stop button, and then press both program buttons.
ACCESS 0000 is shown in the display.
Enter the code 9191.
Enter the numbers using the program buttons; press Stop.
Summary of Contents for DC6-14
Page 1: ...Installation manual Drying Cabinet DC6 14 Original instructions 427001194 EN 2022 03 18 ...
Page 2: ......
Page 4: ......
Page 21: ...Installation manual 21 X X X 0 2x IV X fig W01325 ...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...