28
Installation manual
6.3
Multiple cabinets
If multiple drying cabinets or dryers are connected to the same air duct, a non-return valve must be installed on each
appliance to prevent cold air from entering or the air pressure of one appliance affecting the other.
fig.W01349
Number of
cabinets
1
2
3
4
5
6
7
8
9
10
Exhaust air duct
dia.
(mm)
200
315
315
315
400
400
400
500
500
500
Recommended
area for fresh air
intake
(m
2
)
0.157
0.390
0.390
0.390
0.628
0.628
0.628
0.982
0.982
0.982
Minimum area for
fresh air intake
(m
2
)
0.069
0.139
0.208
0.278
0.347
0.417
0.486
0.556
0.625
0.694