ATS-5X User Manual
Page 36 of 44
Figure 47 – Slope Measurement
2.7.10.2
Setup
There are no restrictions on the line interface setup for this measurement.
The following transmit modes are permitted for this measurement:
Off
Slope
2.7.10.3
Measurements and Controls
The following measurements are shown on the screen and updated continuously:
Receive freq
:
The frequency of the largest single tone at the receiver
Receive level
:
The level of the largest single tone at the receiver, regardless of the
Setup
screen filter
selection.
Receive level at 1004 Hz
: The level of the last 1004 Hz tone that was detected for a sufficient period of time,
regardless of the
Setup
screen filter selection.
Receive level at 404 Hz
:
The level of the last 404 Hz tone that was detected. The display shows the relative level
compared to the
Receive level at 1004 Hz
.
Receive level at 2804 Hz
: The level of the last 2804 Hz tone that was detected. The display shows the relative
level compared to the
Receive level at 1004 Hz
.
The following controls are shown on the screen:
Back
:
Return to the previous screen
Save
:
Store the Slope measurement results in text format to the USB flash inserted in the ATS-5X
USB port. If no valid drive is attached, a message is displayed to indicate this.
Setup
:
Show the
Setup
screen.
3
Maintenance
3.1
Software Update
NOTE: EXCERCISE CAUTION DURING THE SOFTWARE UPDATE! IF THE SOFTWARE UPDATE
PROCESS IS INTERRUPTED, THE ATS-5X CAN BE RENDERED INOPERABLE AND MUST BE
RETURNED TO THE FACTORY FOR REPAIR.