Electro-Voice Zx1i-100T Installation Manual Download Page 9

ZX1i Series Loudspeaker

Installation and wiring | en

9

Electro-Voice

Installation Manual

2022-01 | 04 | F.01U.177.815

2.2.2

Selecting the voltage tap

Figure 2.1: 

Voltage tap selector (ZX1i-90T and ZX1i-100T models only)

Selecting the voltage tap applies only to ZX1i-90T and ZX1i-100T models.
Before attaching the speaker to the bracket:

4

Select the proper voltage tap setting for your installation.

The voltage selector switch is located at the rear of the speaker below the input terminal
panel. A rotary switch on the back panel selects the taps.

Available voltage taps:

At 100 V:

12.5 W

25 W

50 W

100 W

At 70.7 V:

6 W

There is also an 8-ohm bypass setting.
A guide on the back of each speaker shows which switch positions to use for the power
settings at 70 V and 100 V.

2.2.3

Selecting the horn dispersion orientation

For the 90° x 50° horn version you may rotate the horn assembly for more effective coverage,
depending on the orientation of the speaker cabinet in your installation. The horn is factory-
installed with the 90° coverage in the horizontal plane and the 50° coverage in the vertical
plane.

To rotate the horn:

1.

Remove the logo badge.

2.

Remove the grille mounting screws.

3.

Remove the steel grille.

4.

Remove the horn mounting screws.

5.

Rotate the horn 90°.

6.

Secure the horn back to the baffle with the horn mounting screws.

7.

Secure the steel grille to the baffle with the grille mounting screws.

8.

Secure the logo badge back onto the steel grille.

Summary of Contents for Zx1i-100T

Page 1: ...ZX1i Series Loudspeaker en Installation Manual...

Page 2: ......

Page 3: ...m 7 2 2 Step by step installation 7 2 2 1 Mounting the QuickSAM bracket to the mounting surface 7 2 2 2 Selecting the voltage tap 9 2 2 3 Selecting the horn dispersion orientation 9 2 2 4 Attaching th...

Page 4: ...loth and weatherized components allows both indoor and outdoor use An optional weatherized input panel cover with a gland nut is available for additional protection Installing the ZX1i is quick and ea...

Page 5: ...50 rotatable horn Black or white models Phoenix input connector ZX1i 90T_HE ZX1i 90TW_HE 90 x 50 rotatable horn 100 W transformer with 8 ohm bypass and Automatic Saturation Compensation ASC Black or w...

Page 6: ...m overview A Sweep adjustment bolt socket head bolt A B Enclosure attachment and rotation adjustment bolt socket head bolt B C Dual low frequency ports D Durable zinc alloy steel grille E Cast aluminu...

Page 7: ...p installation 2 2 1 Mounting the QuickSAM bracket to the mounting surface Warning It is the installer s responsibility to ensure that the mounting surface is stable and can support more than the spea...

Page 8: ...wiring ZX1i Series Loudspeaker 2022 01 04 F 01U 177 815 Installation Manual Electro Voice 70 rotation range 90 sweep range 70 90 Refer to Selecting the voltage tap page 9 Selecting the horn dispersio...

Page 9: ...so an 8 ohm bypass setting A guide on the back of each speaker shows which switch positions to use for the power settings at 70 V and 100 V 2 2 3 Selecting the horn dispersion orientation For the 90 x...

Page 10: ...10 en Installation and wiring ZX1i Series Loudspeaker 2022 01 04 F 01U 177 815 Installation Manual Electro Voice 6 3 4 8 1 5 7 2 Figure 2 2 Horn rotation 90 x 50 models only...

Page 11: ...the sweep axis by tightening the socket head bolt A 4 Select the proper vertical angle and secure the rotation axis by tightening the socket head bolt B To tighten the recessed socket head bolt B ins...

Page 12: ...the system 2 2 6 Securing the seismic tab connection point The rear of the enclosure includes an eyebolt for connection to a seismic restraint To secure the seismic tab connection point 1 Connect the...

Page 13: ...and wiring en 13 Electro Voice Installation Manual 2022 01 04 F 01U 177 815 4 Test the complete system operation Refer to Troubleshooting page 15 for assistance in locating many speaker related probl...

Page 14: ...kSAM bracket 1 Loosen the socket head bolt B Refer to System overview page 6 2 Press in the mounting tab while pulling the speaker away from the mounting surface Press in the mounting tab with the inc...

Page 15: ...er for example from a CD player or tuner Connect the test speaker in parallel with the malfunctioning line If the sound level has gone or is very weak the line has a short in it possibly a severe scra...

Page 16: ...ght If the problem persists it may be in the amplifier or wiring Refer to Problem 1 4 Constant noise such as buzzing hissing humming Defective amplifier or other electronic device If the noise is pres...

Page 17: ...line kerosene acetone MEK paint thinner harsh detergents solvents or other chemicals as these agents may cause permanent damage to the enclosure 4 2 Painting The ZX1 is made of high impact polystyrene...

Page 18: ...peak LF transducer EV8L 203 mm 8 in driver HF transducer DH2005 25 mm 1 in exit compression driver Crossover frequency 1 7 kHz Nominal impedance 8 Minimum impedance 6 T version transformer taps rated...

Page 19: ...7 815 Dimensions H x W x D 451 mm x 282 mm x 263 mm 18 in x 11 in x 10 in Net weight 8 4 kg 18 5 lb without transformer 10 4 kg 23 0 lb with transformer Shipping weight 10 2 kg 22 5 lb without transfo...

Page 20: ...20 Technical data ZX1i Series Loudspeaker 2022 01 04 F 01U 177 815 Installation Manual Electro Voice...

Page 21: ...ZX1i Series Loudspeaker Technical data 21 Electro Voice Installation Manual 2022 01 04 F 01U 177 815...

Page 22: ...22 Technical data ZX1i Series Loudspeaker 2022 01 04 F 01U 177 815 Installation Manual Electro Voice...

Page 23: ......

Page 24: ...osch Ring 5 85630 Grasbrunn Germany www boschsecurity com Bosch Sicherheitssysteme GmbH 2022 Bosch Security Systems LLC 12000 Portland Avenue South Burnsville MN 55337 USA www electrovoice com Bosch S...

Reviews: