background image

PROFESSIONAL POWER AMPLIFIER

8    Owner‘s Manual

2.2 Operating Voltage

The power amplifier receives its power supply via the Mains input. Only the provided power cord may be used. During
installation, always separate the power amplifier from the mains. Connect the power amplifier only to a mains network, which
corresponds to the requirements indicated on the type plate.

2.3 Mains Switch

The Mains Switch on the front panel separates the power amp from the mains. Turning
the Mains Switch to ON starts booting up the power amp. A soft start circuit compensates
mains inrush current peaks and thus prevents the automatic cutout of the mains from
reacting when switching on the power amplifier. Speaker system switch-on is delayed by
approximately 2 seconds via output relays, effectively suppressing any possible power-on
noise, which otherwise might be heard through the loudspeakers. PROTECT-LED lights
up and fans are at high speed during this delay. This indicates all protections are working
fine.

2.4 Mounting

Q amplifiers have been designed for installation in a conventional 19-inch rack case. Attach the power amp with its frontal
rack mount ears using 4 screws and washers as shown in following illustration.
Additionally securing the amplifier at the rear becomes necessary, if the rack case in which the power amplifier has been
installed will be transported. Failure to do so may result in damage to the power amplifier as well as to the rack case. Attach
the power amp as shown in the illustration using 4 case nuts and screws. Brackets for securing the power amplifier are
available as accessories.

2.5 Ventilation

As with all Electro-Voice power amps with fan cooling, the airflow direction is
front-to-rear, obviously because there is more cold air outside of the rack case
than inside. The power amplifier remains cooler and dissipating the developing
waste heat in a specific direction gets easier. In general, setting up or mounting
the power amplifier has to be done in a way that fresh air can enter unhindered at
the front and exhausted air can exit at the rear. When installing the power amp in
a case or rack system, attention should be paid to these details to provide
sufficient ventilation. Allow for an air duct of at least 60 mm x 330 mm between
the rear panel of the power amplifier and the inner wall of the cabinet/rack case.
Make sure that the duct reaches up to the cabinet’s or the rack case’s top
ventilation louvers. Leave room of at least 100 mm above the cabinet/rack case for ventilation. Since temperatures inside of
the cabinet/rack case can easily rise up to 40 °C during operation of the power amp, it is mandatory to bear in mind the
maximum allowable ambient temperature for all other appliances installed in the same cabinet/rack case.

CAUTION:
Blocking/closing the power amp’s ventilation louvers is not permissible. Without sufficient coo-
ling/ventilation, the power amplifier may automatically enter protect mode. Keep ventilation lou-
vers free from dust to ensure unhindered airflow.
Do not use the power amplifier near heat sources, like heater blowers, stoves or any other heat
radiating devices.
To ensure trouble-free operation, make certain that the maximum allowable ambient
temperature of +40°C is not exceeded.

Summary of Contents for Q1212

Page 1: ...OWNER S MANUAL BEDIENUNGSANLEITUNG ...

Page 2: ......

Page 3: ... Output Cabeling 9 Audio Input Cabeling 10 Operation 12 Volume Control 12 Indications 12 FAN Cooling 12 INHALT Beschreibung 16 Willkommen 16 Auspacken und Inspektion 16 Lieferumfang und Garantie 16 Eigenschaften Beschreibung 16 Verantwortung des Betreibers 16 Installation 17 Bedienelemente Anzeigen und Anschlüsse 17 Betriebsspannung 18 Netzschalter 18 Einbau 18 Kühlung 18 Groundlift 19 LPN Filter ...

Page 4: ...60065 VDE 0860 IEC 65 and the CSA E65 94 have to be obeyed when servicing the appliance 2 Use of a mains separator transformer is mandatory during maintenance while the appliance is opened needs to be operated and is connected to the mains 3 Switch off the power before retrofitting any extensions changing the mains voltage or the output voltage 4 The minimum distance between parts carrying mains v...

Page 5: ...ve for a variety of mobile and club sound systems like e g ZX Tour X and Phoenix loudspeaker families Their comprehensive protection system includes circuitry against overheating overload short circuit HF and DC as well as back EMF and inrush current Loudspeakers are protected by turn on delay relays The build in patented LPN Low Pass Notch filter compensates for transient distortion in dynamic si...

Page 6: ...t does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to...

Page 7: ...s A and B 2 Level Indicators for channels A and B 3 Protections Indicator PROTECT 4 Power On Off Indicator POWER 5 Mains Switch 1 Mains Input 2 Ground Lift Switch CIRCUIT TO CHASSIS SWITCH 3 Type Plate 4 Audio Inputs INPUT A INPUT B 5 Audio Outputs OUTPUT A OUTPUT B 6 Power Amp Mode Switch MODE 7 LPN Filter Switch LPN 8 Power Amp Outputs Speakon CHANNEL A CHANNEL B ...

Page 8: ...nd screws Brackets for securing the power amplifier are available as accessories 2 5 Ventilation As with all Electro Voice power amps with fan cooling the airflow direction is front to rear obviously because there is more cold air outside of the rack case than inside The power amplifier remains cooler and dissipating the developing waste heat in a specific direction gets easier In general setting ...

Page 9: ... like stereo operation Using the input level controls on the power amp s front panel allows independently adjusting the channels amplification PARALLEL In PARALLEL mode the inputs of channel A and channel B are directly electrically linked The audio signal has to be applied to the input connectors of channel A Using the input level controls to independently control the amplification of the two cha...

Page 10: ...d no interfering signals are to be expected in the vicinity of the power amplifier In this case bridging the screen shielding and the pin of the inverting input inside of the connector is Speakon CHANNEL B Speakon CHANNEL A 1 1 Connector 1 1 2 2 B B Signal A A B B Table 2 1 Speaker connection using Speakon A and B connectors CAUTION In BRIDGED mode the input signal has to be fed to input channel A...

Page 11: ...anced cabling and connections is always preferable Next to its input connector each channel provides an individual XLR type connector OUTPUT A or OUTPUT B which is connected in parallel to allow for comfortably daisy chaining the audio signal for the connection of additional audio equipment Illustration 2 2 Unbalanced connection of input Illustration 2 3 Balanced connection of output Daisy Chain 3...

Page 12: ...l levels of each channel at 40dB 30dB 20dB and 10dB below full modulation and 0dB as soon as full modulation is reached 0dB indication results from comparing the power amp s internal ratio of input to output voltage which ensured precise indication of the full modulation limit even before limiting becomes audible The LIMIT LED lights as soon as the integrated dynamic audio limiter is activated and...

Page 13: ...PROFESSIONAL POWER AMPLIFIER Owner s Manual 13 ...

Page 14: ... 16 Verantwortung des Betreibers 16 Installation 17 Bedienelemente Anzeigen und Anschlüsse 17 Betriebsspannung 18 Netzschalter 18 Einbau 18 Kühlung 18 Groundlift 19 LPN Filter Low Pass Notch 19 Betriebsart MODE und Verkabelung des Audio Ausgangs 19 Verkabelung des Audio Eingangs 21 Betrieb 22 Eingangspegel Regler 22 Anzeigen 22 Lüfter 22 Specifications Technische Daten 23 ...

Page 15: ...erwendung durch qualifiziertes Servicepersonal Um die Gefahr eines elektrischen Schlages zu vermeiden führen Sie keine Wartungsarbeiten durch die nicht in der Bedienungsanleitung beschrieben sind außer Sie sind hierfür qualifiziert Überlassen Sie sämtliche Servicearbeiten und Reparaturen einem ausgebildeten Kundendiensttechniker 1 Bei Reparaturarbeiten im Gerät sind die Sicherheitsbestimmungen nac...

Page 16: ...ce bieten eine hohe stabile Ausgangsleistung bei hohem Wirkungsgrad auf hohem Performance Niveau Sie eignen sich somit ideal als Antrieb für eine Vielzahl von Mobil und Clubsystemen wie z B für Lautsprecher der ZX Tour X und Phoenix Familien Die Endstufen der Q Serie sind gegen Überhitzung Überlast Kurzschluss sowie Hochfrequenz und Gleichspannung am Ausgang geschützt Eine Beschädigung der Endtran...

Page 17: ... bzw B 2 Pegelanzeige für Kanal A bzw B 3 Anzeige Schutzschaltung PROTECT 4 Anzeige Betrieb POWER 5 Netzschalter 1 Netzeingang 2 Schalter Groundlift CIRCUIT TO CHASSIS SWITCH 3 Typenschild 4 Audioeingangsbuchsen INPUT A INPUT B 5 Audioausgangsbuchsen OUTPUT A OUTPUT B 6 Schalter Betriebsart MODE 7 Schalter LPN Filter LPN 8 Endstufenausgangsbuchsen Speakon CHANNEL A CHANNEL B ...

Page 18: ...entwickelt Befestigen Sie die Endstufe an der Vorderseite mit 4 Schrauben und Unterlegscheiben wie in folgender Abbildung dargestellt Wird das Rack in dem die Endstufe eingebaut ist transportiert muss die Rückseite der Endstufe im Rack befestigt werden Bei fehlender Befestigung kann sowohl die Endstufe als auch das Rack beschädigt werden Befestigen Sie die Endstufe wie in nebenstehender Abbildung ...

Page 19: ...ückseite bestimmt die Betriebsart der Endstufe Mögliche Schalterstellungen sind DUAL PARALLEL und BRIDGED DUAL In der Betriebsart DUAL arbeiten beide Kanäle der Endstufe unabhängig voneinander Diese Betriebsart wird bei allen 2 kanaligen Anwendungen wie Stereobetrieb verwendet Über die Eingangspegel Regler an der Frontseite der Endstufe lässt sich die Verstärkung der Kanäle getrennt justieren PARA...

Page 20: ...autsprechern die im aktiv 2 Weg Betrieb verwendet werden Bi Amp Die korrekte Anschlussweise für diese Betriebsart ist zusätzlich auf der Endstufe selbst abgebildet BRIDGED In der Betriebsart BRIDGED werden die beiden Endstufenkanäle im Gegentakt betrieben um eine Verdoppelung der Ausgangsspannung mit einer bis zu vierfach höheren Ausgangsleistung zu erreichen Das Eingangssignal ist über den Eingan...

Page 21: ...mer Netzzuführungen HF Steuerleitungen usw ist jedoch eine symmetrische Verkabelung immer zu bevorzugen Zusätzlich zu den Eingängen steht für jeden Kanal jeweils eine parallel geschaltete XLR Buchse OUTPUT A bzw OUTPUT B zur Verfügung Über diese kann das Audiosignal komfortabel zu anderen Geräten weitergeführt werden Daisy Chain ACHTUNG Im Brückenbetrieb darf die angeschlossene Last 4 Ω nicht unte...

Page 22: ...sgrenze erreicht ist Die 0 dB Anzeige wird endstufenintern aus einem Vergleich von Ausgangsspannung zu Eingangsspannung gewonnen und zeigt somit präzise die Aussteuerungsgrenze an noch bevor eine hörbare Begrenzung auftritt Die LIMIT LED leuchtet auf sobald einer der eingebauten dynamischen Audio Limiter anspricht und die Endstufe über der Aussteuerungsgrenze oder generell im Grenzbereich betriebe...

Page 23: ...kHz Voltage Gain ref 1 kHz 32 0 dB Input Sensitivity rated power 8 Ω 1 kHz 2 2 dBu 1 0 Vrms 3 1 dBu 1 11 Vrms 5 1 dBu 1 39 Vrms 6 6 dBu 1 66 Vrms THD at rated output power MBW 80 kHz 1 kHz 0 03 IMD SMPTE 60 Hz 7 kHz 0 1 DIM30 3 15 kHz 15 kHz 0 05 Maximum Input Level 21 dBu 8 69 Vrms Crosstalk ref 1 kHz at rated output power 80 dB Frequency Response ref 1 kHz 10 Hz 40 kHz 1 dB Input Impedance activ...

Page 24: ...PROFESSIONAL POWER AMPLIFIER 24 Owner s Manual Bedienungsanleitung Block Diagram Blockschaltbild ...

Page 25: ...PROFESSIONAL POWER AMPLIFIER Owner s Manual Bedienungsanleitung 25 Dimensions Abmessungen ...

Page 26: ...PROFESSIONAL POWER AMPLIFIER 26 Owner s Manual Bedienungsanleitung ...

Page 27: ...PROFESSIONAL POWER AMPLIFIER Owner s Manual Bedienungsanleitung 27 ...

Page 28: ...stems Telex EVI Audio Shanghai Ltd Room 3105 3109 No 1 Building No 218 Tian Mu West Road Shanghai China PC 200070 Phone 86 21 6317 2155 Fax 86 21 6317 3023 Europe Africa Middle East Germany Bosch Communications Systems EVI Audio GmbH Hirschberger Ring 45 D 94315 Straubing Germany Phone 49 9421 706 0 Fax 49 9421 706 265 Hong Kong Telex EVI Audio HK Ltd Unit 5 1 F Topsail Plaza 11 On Shum Street She...

Reviews: