Electro Industries Shark ST40 Quick Start Manual Download Page 1

     

Doc

#    

E183703   V.1.01     

          

             QS - 1

                    Shark

®

 

ST40 Meter Quickstart

Electro 

Industries/GaugeTech

Powered by Innovation™

Shark® ST40 Meter Quickstart Guide

                  CAUTION! 

Installation of the Shark® ST40 meter must be performed only by qualified 

                  personnel who follow standard safety precautions during all procedures. Those personnel should
                  have appropriate training and experience with high voltage devices. Appropriate safety gloves,
                  safety glasses and protective clothing are recommended.

 During normal operation of the ST40 meter, dangerous voltages flow through many parts of the unit, includ-
 ing: Terminals and any connected CTs (Current Transformers) and PTs (Potential Transformers), all I/O 
 Modules and their circuits. All Primary and Secondary circuits can, at times, produce lethal voltages and 
 currents. Avoid contact with any current-carrying surfaces.

 Do not use the meter or any I/O device for primary protection or in an energy-limiting capacity. The meter can
 only be used as secondary protection. 

 IMPORTANT! 

Refer to your meter’s Installation and Operation Manual for additional safety warnings before 

 performing installation, wiring, or maintenance of your meter. See the link to the manual, below.

NOTE

: This Quickstart Guide gives basic installation, wiring, and programming instructions.For additional 

meter operation and programming information, refer to your meter’s

 Installation and Operation Manual

 and 

the 

Communicator PQA

TM

, MeterManagerPQA

TM

, and EnergyPQA.com

TM

 Software User Manual

 on EIG’s website: 

User Manual:

https://www.electroind.com/products/st40/

From the webpage, click Technical Documents>User Manual.

Software Manual:

https://www.electroind.com/products/communicatorpqa-software-application-5/

From the webpage, click Technical Documents>User Manual.

CommunicatorPQA

TM

 Setup Software:

https://www.electroind.com/products/communicatorpqa-software-application-5/

From the webpage, click Download ComPQA Pro. To get a Professional license for the software, email 
[email protected] or call 516-334-0870.

All EIG’s metering and software products’ literature can be accessed from:

https://www.electroind.com/all-products/

For software and metering integration, EIG’s Technical Support Engineers are available on an hourly or daily 
basis to help with typical commissioning assistance, which includes:

• Verifying meter installation and wiring.

• Verifying proper system integration.

• Working with 3rd parties to ensure cross compatibility.

• Advising users on best practices for optimal implementation.

You can reach Technical Support from 8 a.m. to 8 p.m. EST, Monday-Friday, at 516-334-0870.

Summary of Contents for Shark ST40

Page 1: ...w NOTE This Quickstart Guide gives basic installation wiring and programming instructions For additional meter operation and programming information refer to your meter s Installation and Operation Manual and the Communicator PQATM MeterManagerPQATM and EnergyPQA comTM Software User Manual on EIG s website User Manual https www electroind com products st40 From the webpage click Technical Document...

Page 2: ... 5 63 7 216 25 32 5 6833 5 7 1 9 WYE Delta 4 wire 3 PTs 3 CTs DUWK URXQG DUWK URXQG 2 2 2 1 1 9 5 9 9 9 6HUYLFH HOWD LUH ZLWK 1R 37V 7V 86 6 1 2 9 9 9 9 9 7 6KRUWLQJ ORFN 6 7 5 5 72 6 257 1 2 16758 7 216 72 33 6 2576 9 86 RU UDWLQJV VHH 9ROWDJH XVHV RQ SDJH 1 1 875 5 5 72 0 7 5 63 7 216 25 32 5 6833 5 7 1 1 1RW FRQQHFWLRQ WR PHWHU Delta 3 wire No PTs 2 CTs DUWK URXQG DUWK URXQG 2 2 2 1 1 9 5 9 9 9...

Page 3: ...minator screen CT d This setting is display only it can t be changed 6 Press the ENTER button to go to the CT Scaling setting screen CT S The current Scaling is shown in the second line Press the DOWN ARROW to choose another value You can choose 1 10 or 100 7 Press the ENTER button to go to the PT numerator setting screen Pt n The current PT numerator is shown in the second line To change the sett...

Page 4: ...600 choose this for RS485 connection 19 2 19200 38 4 38400 or 57 6 57600 If you have the Ethernet option keep this as 57 6 13 Press the ENTER button to go to the meter Protocol setting screen Prot The meter s current Protocol is shown in the second and third lines Press the DOWN ARROW to choose another communication Protocol You can choose Mod rtU Modbus RTU choose this for RS485 or Ethernet conne...

Page 5: ...mmunicatorPQATM soft ware Use either the RS485 port or the USB port to make the physical connection to your PC Note that your meter will have either RS485 OR Ethernet it will always have a USB port For Ethernet communi cation connect first via the USB port and then see the ST40 User Manual for instructions on setting up Ethernet communication Connect through the RS485 Port The ST40 meter s RS485 p...

Page 6: ...he Device Status screen and then click the Profile icon in the Icon Bar 5 The meter s Device Profile screen opens giving you access to the programmable settings for the meter NOTE A few basic settings are explained here Refer to the CommunicatorPQATM MeterManagerPQA and EnergyPQA com Software User Manual see page QS 1 for the download link or click Help Con tents from the top of the CommunicatorPQ...

Page 7: ...ersal for any phase This feature is useful if a CT is wired the wrong way and you do not want to or cannot change the wiring This setting is only available for a three element WYE hookup For any other hookup this setting will be ignored Program Communications Setting 1 From the Device Profile screen double click General Settings Communications one of the listed ports The settings shown here are fo...

Page 8: ...ch meter individually since the meter name is used to name the log databases when logs are downloaded IMPORTANT When you have made changes to the meter s Device Profile click Save Profile at the bottom left of the Device Profile screen to send the new settings to the meter The meter will reboot and then you can reconnect to it Shark is a registered trademark of Electro Industries GaugeTech EIG Com...

Reviews: