ElectrIQ PD30E User Manual Download Page 15

14 

 

Does the tank full indicator 
is red? 

 

Tank  full,  float  displaced  or  tank  not 
properly  inserted.  Empty  tank,  check 
float  and  make  sure  tank  is  properly 
inserted in unit.

 

Dehumidifier 
does  not  extract 
water 

Is the unit set to a humidity 
level lower than the one in 
the room?

 

Set the humidity level on the humidistat 
bellow current humidity reading.

 

Is the temperature too low 
for  water  extraction  to  be 
efficient?

 

Increase  temperature  in  the  room  or 
reposition the unit.

 

Is  any  intake  grill  or 
discharge  blocked?  Is  the 
unit too close to walls.

 

Remove  obstructions  and  restart  the 
unit.   
Ensure  a  distance  of  at  least  20  [cm 
between the unit & walls

 

Airflow 

seems 

weak 

Is filter dirty or clogged?

 

Please service the filters regularly as per 
user manual.

 

Unit 

is 

noisy 

during operation 

Is  the  unit  on  uneven 
surface?

 

Please place on flat horizontal surface. 

 

Is filter clogged?

 

Please service the filters regularly as per 
user manual.

 

Humidity 

set 

lower  than  the 
room  humidity 
and 

unit 

not 

extracting

 

Humidity sensor error 

Unplug  the  unit  and  plug  it  back  in.  If 
error repeats, call for service centre. 

Incorrect 
temperature 

Temperature sensor error 

Unplug  the  unit  and  plug  it  back  in.  If 
error repeats, call for service centre. 

Unit 

stops 

regularly     

Unit is defrosting 

Allow the unit to automatically  defrost. 
The protect will clear after the unit self 
defrosts.  Increase  temperature  in  the 
room if this repeats too often 

Tank  full  red 
light 

Water tank full notification 

Tank  is  full  or  is  not  in  the  right 
position-- Empty the tank and replace in 
the right position. 

Any  other  malfunctions  will  need  to  be  reported  to  ElectrIQ  service  centre.  Do  not 
attempt unauthorised repairs as these may invalidate the warranty.

 

 

All manuals and user guides at all-guides.com

Summary of Contents for PD30E

Page 1: ...s per day USER MANUAL Thank you for choosing ElectrIQ Please read this user manual before using our innovative Dehumidifiers and keep it safe for future reference Visit our page www electrIQ co uk for...

Page 2: ...ions 2 Features 2 Installation 5 Parts and Control Panel 6 Operation reference guide 8 Positioning 10 Water Drainage 11 Care and Maintenance 12 Troubleshooting 13 Technical Data 15 All manuals and use...

Page 3: ...and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety Do not leave children unsupervised with this applianc...

Page 4: ...dehumidifier must not be used in spaces where there is a high concentration of gases solvent or other volatile organic compounds in very dusty environments in any domestic commercial or industrial en...

Page 5: ...essed handles for improved mobility 6 Intelligent CPU controlled digital humidistat with continuous mode 4 humidity settings 40 50 60 70 RH and room humidity and temperature display 7 Quiet vs turbo f...

Page 6: ...ract water from the environment The compressor dehumidifiers are ideal for normal domestic office or commercial applications in heated spaces during the winter months and they operate very economicall...

Page 7: ...ir Inlet and Filters 5 Recessed Handle 6 Rear case 7 Permanent drainage 8 Water tank 9 Castors 10 Power cord and plug varies according to region Filters 1 Washable mesh filter 2 Activated carbon filte...

Page 8: ...tor performs the following functions 1 When the unit is plugged in it will indicate the room humidity level 2 When the humidity level is selected it will indicate the set humidity than will revert to...

Page 9: ...drying boost on initial run or emergencies not recommended for long normal operation in domestic office environment Humidity set to 50 RH recommended setting great for domestic operation and dry stor...

Page 10: ...ut once every 30 minutes When the unit is running in a room with temperature between 12 C and 20 C unit may enter the defrost mode about once every 45 minutes Normal operation will resume after defros...

Page 11: ...f excessive moisture as soon as it is turned on Excess moisture is dispersed throughout your home For this reason the dehumidifier should be positioned in a central and clear location so that it can d...

Page 12: ...ed when the tank is restored in its correct position NOTES When you remove the bucket do not touch sensors or any parts which are situated behind tank Doing so may damage the product Be sure to push t...

Page 13: ...asoline as they may cause irreversible damage to the unit Clean the Grille and Case and Maintain the filters Use water and a mild detergent Do not use bleach or abrasives Do not splash water directly...

Page 14: ...running in dehumidifying mode with a low room temperature Please check if the room temperature is lower than 5 C If so the unit will stop working while in dehumidifying mode unit may be defrosting Th...

Page 15: ...on Is the unit on uneven surface Please place on flat horizontal surface Is filter clogged Please service the filters regularly as per user manual Humidity set lower than the room humidity and unit no...

Page 16: ...ispose this product as unsorted waste Collection of such waste must be handled separately as special treatment is necessary Recycling facilities are now available for all customers at which you can de...

Page 17: ...4 Check whether the water tank is full 5 Have you followed the troubleshooting procedures If the unit still fails to operate call 0871 620 1057 or fill the online form Office hours 9AM 5PM Monday to F...

Reviews: