9
The unit will try to maintain humidity level selected in the space where is placed by turning
off the compressor when the desired humidity is reached. Note that according to the size of
the enclosed environment where is used, obstacles in the direct flow, extra humidity being
added in, the settings selected, as well as other environmental factors the results may vary.
Other features and Indicators
Tank Full Light
red light will be on and the unit will beep when the tank is ready to be
emptied, or when the tank is removed or not replaced in the proper position. The
water level control switch shuts off the dehumidifier when the tank is full, or when
the tank is removed or not replaced in the proper position. Empty to resume
normal operation.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the
unit will go in defrost mode.
When the unit is running in a room with temperature between 5⁰C and 12⁰C unit
may enter the defrost mode about once every 30 minutes.
When the unit is running in a room with temperature between 12⁰C and 20⁰C, unit
may enter the defrost mode about once every 45 minutes.
Normal operation will resume after defrost mode. We advise not to use the unit in
unheated rooms where temperature can go close or below 5⁰C as the evaporator
at the back of the unit may freeze and damage the unit.
Humidistat control and fan/ compressor operation
When the selected humidity is lower by than the user selected humidistat setting;
the dehumidifier’s compressor will be shut off automatically but the fan will still
move to ensure air is not stale in the room. The unit will use only a minimal
amount of energy in fan mode.
When the humidity is going back to being equal or higher than user selected
humidity the compressor will restart once the 3 minutes delay compressor
protection expires.
Power
After the unit has stopped, it is not recommended to resume operation in the first
at least 10 minutes. This is to protect the compressor. Operation can resume after
this period lapse. When the unit is restarted there is a 3 minutes delay before
compressor will start.