IMPORTANT SAFETY INFORMATION 

 
Please  read  this  user  manual  before  using  this  heater  and  keep  it  safe  for  future 
reference. 
 

 

Read the following instructions carefully and be sure your patio heater is properly 
installed, assembled and cared for. Retain the instructions for future reference.  

 

Failure  to  follow  these  instructions  may  result  in  serious  bodily  injury  and/or 
property damage.   

 

WARNING - Risk of Suffocation!

 

Gas heaters must be used outdoors and must 

not be used in enclosed areas such as sheds or marquees!   

 

Read the instruction manual before using the appliance.   

 

WARNING: Accessible parts may be very hot. Keep young children away.  

 

This appliance must be kept away from flammable materials during use.   

 

Do not move the appliance during use.   

 

The appliance should be secured to the ground when in use. 

 

Turn off the gas supply at the gas cylinder after use.   

 

Do not modify this appliance.   

 

If you have any questions concerning assembly or operation, consult the retailer 
or Bottled Gas Company.   

 

Always place the appliance and cylinder on flat level ground.   

 

Turn off the gas cylinder if gas leak is suspected.  

 

Parts  sealed  by  the  manufacturer  must  not  be  altered  by  the  user.  No 
modifications  should  be  made  to  any  part  of  this  heater  and  repairs  and 
maintenance  should  only  be  carried  out  by  a  registered  Gas  Safe  service 
engineer.  

 

Use only regulator and hose approved for LP Gas at the correct pressures and 
gas type.  

 

The regulator should comply with the standard EN16129 and current regulations 
in the country where it is installed, which may be found at your nearest retailer of 
gas items.  

 

Refer to the technical data. It is strictly prohibited to use adjustable pressure.  

 

The life expectancy of the regulator is estimated as 10 years. It is recommended 
that the regulator is changed within 10 years of the date of manufacture or the 
national conditions require it. 

 

The type of replaceable hose should be compliant with EN16436-1. 

 

The hose used must conform to the relevant standard for the country of use. The 
length of the hose must be 0.7 meters (minimum) and 1.5 meters (maximum). A 
worn or damaged hose must be replaced. Ensure that the hose is not obstructed 
or kinked. It is recommended that the hose is changed within 1 year of the date 
of manufacture or as the national conditions require. 

 

 
 
 

Summary of Contents for EQODHMBR

Page 1: ...USER MANUAL GAS PATIO HEATER WARNING FOR OUTDOOR USE ONLY OR IN WELL VENTILATED AREAS PLEASE KEEP THE MANUAL FOR FUTURE REFERENCE EQODHMBR EQODHMGR...

Page 2: ...2 CONTENTS SAFETY 3 PARTS LIST 5 ASSEMBLY 6 OPERATION 9 LEAK TESTING 10 GAS INFORMATION 10 MAINTENANCE 11 STORAGE 11 TROUBLESHOOTING 12 TECHNICAL SPECIFICATIONS 13 SUPPORT 13...

Page 3: ...ground Turn off the gas cylinder if gas leak is suspected Parts sealed by the manufacturer must not be altered by the user No modifications should be made to any part of this heater and repairs and m...

Page 4: ...ammable items on this heater DO NOT operate this heater unless it is fully assembled Respect the minimum clearances from combustible materials GENERAL INFORMATION FOR SUCCESSFUL ASSEMBLY Please read t...

Page 5: ...5 PRODUCT OVERVIEW PART DESCRIPTION QUANTITY A Reflector Panel 3 B Reflector Plate 1 C Burner head Assembly 1 D Deck Ring 1 E Wicker table 1 F Wicker tank housing assembly 1 G Post 1 H Wheel kits 1...

Page 6: ...l and any transmit protection must be moved Small deviations in equipment may occur This is no lack of quality but subject to improvements 1 Fix the post G onto the top of wicker tank housing assembly...

Page 7: ...ry to loosen the preassembled bolts prior to assembly and retighten once complete 5 Attach the reflector plate B to reflector panels A using M6 x 8mm screws FF 6 washers DD and cap nuts GG Secure loos...

Page 8: ...e post G using preassembled bolts M5 x 10 HH lock washer JJ and 5 washers EE Note The pressure regulator and hose assembly to be used must conform to local standard codes 8 Secure gas hose and regulat...

Page 9: ...e pilot fails to ignite press and turn the dial clockwise to OFF before repeating the lighting steps TO LIGHT THE PATIO HEATER The pilot should be lit and the dial set to PILOT Hold the dial down and...

Page 10: ...der with a damaged body valve collar or foot ring A dented or rusty gas tank may be hazardous and should be checked by a gas supplier Never connect this appliance to an unregulated gas source When the...

Page 11: ...may create a fire hazard If any carbon deposits develop clean the dome and burner with warm soapy water Note In environments with a high salt content such as near the sea corrosion occurs more quickly...

Page 12: ...Control dial is not in the HIGH position Turn control dial to the HIGH position Burner flame is low Note Do not operate heater below 5 40 F Gas pressure is low Replace the gas cylinder Tank is almost...

Page 13: ...T NL NO PT SE SI SK RO TR CZ FR GB GR IE PT PL AT CH DE AT CH DE NL Category I3 28 30 37 I3B P 30 I3P 37 I3B P 37 I3B P 50 I3P 50 Gas G30 G31 G30 G31 G31 G30 G31 G30 G31 G31 Pressure mbar 28 30 37 30...