16
The piping can be lead out both on the right or the left of
the indoor unit as seen in fig. 1. Please cut off the pipe
hole guards if you are changing the pipe position. The unit
also features alternatives guards for more pipe positioning.
Make sure that the drain pipe is underneath the pipelines.
(Fig.3) (When the drain pipe passes the room interior,
some condensed water might occur to its surfaces if the
humidity is very high).
Tidy up the copper pipes, electrical cables and water
drains and pass them through the piping wall hole drilled
before (fig.2).
Hang the mounting slots of the indoor unit on the wall
mounting bracket making sure is tight in place (fig.3) so
that the hooks at the bottom of the indoor unit match the
hooks of the wall mounting bracket (fig.4)
Notes:
1. The height of the installed unit is recommended to >
200 cm.
2.
Either the indoor unit or the outdoor unit can be higher,
but the height difference must comply with a max. 5
metres level difference.
3. Try to reduce the bending of the pipes as much as
possible so as to avoid possible negative impacts upon
the performances of the unit.
For the quick connectors model the pipes and electrical cables will be encased in a plastic
“umbilical cord” but there will still be need for careful handling of the piping to avoid bends.
INSTALLATION OF THE OUTDOOR UNIT
Try to move the product to the installation location in its original packaging
As the gravity center of the unit is not at the installation center, special caution should be taken
when using hoisting cables to lift it up
During transport, the outdoor unit must not be tilted to over 45 degrees (also do not store the unit
horizontally.
Use expansion bolts to fix the mounting supports on the wall;
Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level;
If the unit is installed on the wall or at the rooftop, the supports have to be firmly fixed so as to
resist earthquake or strong wind.
Dimensions for parallel units installations
300mm(1')min
STANDARD PIPELINES CONNECTION & AIR PURGING
(Only for non-quick connector models (eIQ-9WMINV / eIQ-12WMINV / eIQ-18WMINV eIQ-24WMINV).
Summary of Contents for eIQ-12WMINV
Page 11: ...11 ...
Page 15: ...15 ...
Page 22: ...22 ELECTRICAL WIRING DIAGRAMS eIQ 9WMINV Indoor Unit Outdoor Unit QC ...
Page 23: ...23 ELECTRICAL WIRING DIAGRAMS eIQ 12WMINV QC Indoor Unit Outdoor Unit ...
Page 24: ...24 ELECTRICAL WIRING DIAGRAMS eIQ 18WMINV Indoor Unit Outdoor Unit QC ...
Page 25: ...25 ELECTRICAL WIRING DIAGRAMS eIQ 24WMINV Indoor Unit Outdoor Unit ...