ElectrIQ CD12PW User Manual Download Page 4

 

 

 

should  not  be  used  to  support  the  full 
weight  of  the  dehumidifier.  When 
carrying  the  unit,  it  should  be  kept 
upright and suifficiently supported from 
its base.  

 

The handle should not be used if there 
are any signs of damage to its fixings. 

 

The appliance must be placed in a room 
without sources of ignition (for example: 
open 

flames, 

an 

operating 

gas 

appliance  or  an  operating  electric 
heater). 

 

R290  refrigerant  gas  complies  with 
European environmental directives. 

 

R290 has a low GWP (Global Warming 
Potential) of 3. 

 

The  CD12PW  contains  about  50g  of 
R290 refrigerant gas. 

 

Do not use or store the appliance in an 
unventilated space with an area smaller 
than 4m

2

 per unit.  

 

If  the  appliance  is  installed,  used  or 
stored  in  an  unventilated  room,  the 
room  must  be  such  as  to  prevent 
stagnation 

of 

possible 

leaks 

of 

refrigerant  gas  as  there  could  be  a 
danger  of  fire  or  explosion  should  the 
refrigerant  come  into  contact  with 
electric heaters, stoves or other sources 
of ignition. 

 

Refrigerant gas may be odourless.  

 

Do not use the product and contact the 
retailer  for  advice,  if  damage  has 
occurred  to  the  unit  which  may  have 
compromised the refrigerant system. 

 

Any  repairs  or  maintenance  must  only 
be carried out on the unit by a suitably 
qualified engineer.  Before opening and 
servicing  the  unit  the  authorized 
engineer  must  be  in  possession  of  a 
copy  of  the  manufacturer’s  service 
manual  and  must  follow  the  safety 
information contained within it to ensure 
all hazards are minimized. 

 

The  refrigerant  system  should  not  be 

perforated or punctured. 

 

Do  not  place  the  unit  next  to  heat 
sources (e.g. electrical fires, fireplaces, 
etc.)  

 

Avoid  mishandling  the  dehumidifier. 
Dropping,  throwing  the  unit  can  cause 
damage  to  its  internals  and  increases 
the risks of operating it.  

 

Do  not  store  or  use  gasoline,  petrol, 
paint,  solvents  or  other  flammable 
vapours or liquids in the vicinity of this 
dehumidifier or any other appliance.  

 

This  dehumidifier  must  not  be  used  in 
spaces 

where 

there 

is 

a  high 

concentration of gases, solvent or other 
volatile  organic  compounds;  in  very 
dusty  environments;  in  any  domestic, 
commercial  or  industrial  environment 
where the air composition is flammable.  

 

Due 

to 

continuous 

product 

development the layout and availability 
of features within the app may vary. 

  

ENERGY SAVING AND UNIT SAFETY 

PROTECTION TIPS  

 

 

Do not cover or restrict the airflow from 
the outlet or inlet grills. Do not operate 
and follow troubleshoot procedure if the 
self-opening  louvers  do  not  open  on 
power on.   

 

For 

maximum 

performance 

the 

minimum distance from a wall or objects 
should be 20 cm  

 

Keep the filters or grills of the unit clean. 
Under normal conditions, filters or grills 
should  only  need  cleaning  once  every 
three weeks (approximately).   

 

Since  the  filters  remove  airborne 
particles, 

more 

frequent 

cleaning 

maybe necessary, depending on the air 
quality.  Vacuum  both  the  mesh  and 
optional filters and wash the mesh filters 
with  hot  soapy  water  and  dry  them 
before placing them back in the unit.  

 

 

 

Summary of Contents for CD12PW

Page 1: ...MART APP CONTROL CD12PW 12 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visit our page ww...

Page 2: ...EL 7 QUICK REFERENCE GUIDE 9 OTHER FEATURES AND INDICATORS 10 POSITIONING THE DEHUMIDIFIER 11 WATER DRAINAGE 12 SETTING UP THE WIFI APP 13 CONNECTING USING QUICK CONNECTION 16 CONNECTING USING AP MODE...

Page 3: ...tlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the power cord or plug is damaged Ensure the power co...

Page 4: ...t follow the safety information contained within it to ensure all hazards are minimized The refrigerant system should not be perforated or punctured Do not place the unit next to heat sources e g elec...

Page 5: ...cause allergic reactions like a runny nose eye and throat irritation headaches fatigue and aggravation of asthma Other indoor pollutants include bacteria viruses dust mites and pollen Emissions from...

Page 6: ...rainage Port Power Cord Filter Housing Water Tank CARBON FILTER Replacement filters are available from the retailer under code ACFIL CDPX HEPA FILTER NOT SUPPLIED Filters are available from the retail...

Page 7: ...e 12 15 C This dehumidifier is easy to move around on castors and is designed to extract unwanted humidity while saving money due to it s power saving logic It features an intelligent humidistat where...

Page 8: ...TY SETTING Press the UP and DOWN buttons to select the desired relative humidity level the default relative humidity is 55 When a relative humidity of 35 is selected the compressor will not stop until...

Page 9: ...s that the internal temperature is too low During defrosting the indicator will light up Once the defrost cycle has finished the appliance will return to the mode that was previously operating TANK FU...

Page 10: ...tly measured To achieve drier air or while drying laundry use the DOWN button to select a lower desired humidity e g 35 45 LAUNDRY MODE When drying clothes it is advised for the dehumidifier to operat...

Page 11: ...ally but the fan will continue to operate to ensure that the air within the room is not stale The unit will use only a minimal amount of energy in fan mode When the humidity of the room is equal to or...

Page 12: ...n for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and m...

Page 13: ...into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosure The water...

Page 14: ...ur chosen store Android IOS CONNECTION METHODS AVAILABLE FOR SETUP The smart device has two different setup modes CF Quick Connection and AP Access Point The quick connection is a quick and simple way...

Page 15: ...mail address or phone number and press continue to register 4 A verification code will be sent by the method selected in step 3 Enter the code into the app 6 The app is now registered It will automati...

Page 16: ...CREATING ROOMS 1 Press on the ADD HOME button 2 Type in a name for your home 3 Press on the location button to select the location of your home See SETTING YOUR LOCATION below 4 New rooms can be added...

Page 17: ...2 Select the type of device as Dehumidifier in the Small Home Appliance tab 3 Ensure the WiFi light on the dehumidifier is flashing twice per second then press on the orange button at the bottom of t...

Page 18: ...idifier 3 Press on the AP mode button in the top right of the screen 4 Ensure the WiFi light on the dehumidifier is slowly flashing once per second then press on the orange button at the bottom of the...

Page 19: ...18 CONTROLLING YOUR DEVICE THROUGH THE APP THE HOME SCREEN Add a device Choose the device to control Smart Scenes Automation User Profile...

Page 20: ...e Change the operating mode between Smart dehumidify Air purify and laundry Desired Humidity Change the desired humidity between 35 C and 80 C Oscillation Set the position of the louvres Room Humidity...

Page 21: ...preset configurations Below is an example of how to set up a scene 1 Press on the Smart Scene tab at the bottom of the Home screen 3 Select Scene to create a new Scene 2 Press on the Plus in the top...

Page 22: ...ext to Please Enter Scene Name to input the name for your Scene Press the Red Plus next to When any condition is satisfied to add the trigger Press the Red Plus next to Execute following actions to ad...

Page 23: ...ou are also able to change settings related to the app itself CONNECTION TROUBLESHOOTING 1 Check whether the device is powered on and is in the correct standby mode if not please refer to the CHANGING...

Page 24: ...over gently approximately every 2 3 weeks If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit When filter c...

Page 25: ...re a distance of at least 20 cm between the unit walls Airflow seems weak Are the filters dirty or clogged Please service the filters regularly as per the user manual Unit is noisy during operation Is...

Page 26: ...ll stop working while in dehumidifying mode unit may be defrosting The ambient operating range is between 5 C and 35 C with a relative humidity ranging from 30 to 80 For maximum efficiency use the uni...

Page 27: ...Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipmen...