ElectrIQ CD12PW User Manual Download Page 10

 

 

 

QUICK REFERENCE GUIDE 

 
 Power Button: 

Press to turn the dehumidifier on and off.   

 

 

Timer

: Press the timer button, then use the  

 buttons to adjust the duration of 

the timer (1-24 hrs, start/ stop timer).  

 

If set while the unit is running

: The number will represent the number of hours the unit will operate before 

turning off. This will not be affected if the unit enters defrost mode or the tank is emptied and reinserted.  

 

If set while the unit is in standby:

 the set number represents the period in hours after which the unit will 

start. To cancel start / stop mode press the timer key again.  

 
 

Up  and  Down  Buttons:

  During  the  High  or  Low  modes  when  the  unit  is 

displaying the current relative humidity, these buttons can be used to adjust the 
desired humidity level. The desired relative humidity can be set between 35 and 
80% in 5% increments.   

 

 

SMART Mode:

 This is designed for maximum convenience and defaults to the 

ideal  domestic  environment  humidity  level  of  50-55%  while  saving  electricity. 
This is the default mode and is recommended for most users. 
   

During operation the compressor will operate until the desired humidity is reached and then will stop.  The 

fan moves the air around the room ensuring the entire air in the room is processed and humidity correctly 
measured.   

 
To achieve drier air, or while drying laundry use the DOWN button to select a lower desired humidity (e.g. 

35-45%).  

 

LAUNDRY  MODE:

  When  drying  clothes  it  is  advised  for  the  dehumidifier  to  operate  continuously  with 

maximum water extraction until the water tank is full. Set the unit to the Smart mode, and set the desired 
humidity level between 35%-50%. 35% is very dry and is hardly achievable in a UK domestic environment. 
As such the unit will work until the water tank is full when set to 35%. Do not place clothes directly over any 
of the vents on the dehumidifier. Make sure that there is nothing blocking the hot air exhaust air flow and 
for best results place the laundry within 1.5 meters of the dehumidifier.  

 

 

NOTES:  

 

If a permanent drainage pipe is fitted the unit will not stop operating. Setting the desired humidity to 
around 35% is good for laundry mode, a quick drying boost, or in emergencies. It is not recommended 
for long normal operation in a domestic or office environment.  

 

To allow more moisture in the air, press the up button and set to a higher desired humidity (e.g. 60-
70%).  

 

We recommend setting the Humidity to 50-55%.  This is great for domestic operation and dry 
storage. 

 

Setting the humidity to 60% is great for personal comfort and applications where 50% RH is 
considered too dry.  

 

Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is needed 
without the need to reduce the humidity further.  

 

 

Summary of Contents for CD12PW

Page 1: ...MART APP CONTROL CD12PW 12 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future reference Visit our page ww...

Page 2: ...EL 7 QUICK REFERENCE GUIDE 9 OTHER FEATURES AND INDICATORS 10 POSITIONING THE DEHUMIDIFIER 11 WATER DRAINAGE 12 SETTING UP THE WIFI APP 13 CONNECTING USING QUICK CONNECTION 16 CONNECTING USING AP MODE...

Page 3: ...tlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the power cord or plug is damaged Ensure the power co...

Page 4: ...t follow the safety information contained within it to ensure all hazards are minimized The refrigerant system should not be perforated or punctured Do not place the unit next to heat sources e g elec...

Page 5: ...cause allergic reactions like a runny nose eye and throat irritation headaches fatigue and aggravation of asthma Other indoor pollutants include bacteria viruses dust mites and pollen Emissions from...

Page 6: ...rainage Port Power Cord Filter Housing Water Tank CARBON FILTER Replacement filters are available from the retailer under code ACFIL CDPX HEPA FILTER NOT SUPPLIED Filters are available from the retail...

Page 7: ...e 12 15 C This dehumidifier is easy to move around on castors and is designed to extract unwanted humidity while saving money due to it s power saving logic It features an intelligent humidistat where...

Page 8: ...TY SETTING Press the UP and DOWN buttons to select the desired relative humidity level the default relative humidity is 55 When a relative humidity of 35 is selected the compressor will not stop until...

Page 9: ...s that the internal temperature is too low During defrosting the indicator will light up Once the defrost cycle has finished the appliance will return to the mode that was previously operating TANK FU...

Page 10: ...tly measured To achieve drier air or while drying laundry use the DOWN button to select a lower desired humidity e g 35 45 LAUNDRY MODE When drying clothes it is advised for the dehumidifier to operat...

Page 11: ...ally but the fan will continue to operate to ensure that the air within the room is not stale The unit will use only a minimal amount of energy in fan mode When the humidity of the room is equal to or...

Page 12: ...n for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and m...

Page 13: ...into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosure The water...

Page 14: ...ur chosen store Android IOS CONNECTION METHODS AVAILABLE FOR SETUP The smart device has two different setup modes CF Quick Connection and AP Access Point The quick connection is a quick and simple way...

Page 15: ...mail address or phone number and press continue to register 4 A verification code will be sent by the method selected in step 3 Enter the code into the app 6 The app is now registered It will automati...

Page 16: ...CREATING ROOMS 1 Press on the ADD HOME button 2 Type in a name for your home 3 Press on the location button to select the location of your home See SETTING YOUR LOCATION below 4 New rooms can be added...

Page 17: ...2 Select the type of device as Dehumidifier in the Small Home Appliance tab 3 Ensure the WiFi light on the dehumidifier is flashing twice per second then press on the orange button at the bottom of t...

Page 18: ...idifier 3 Press on the AP mode button in the top right of the screen 4 Ensure the WiFi light on the dehumidifier is slowly flashing once per second then press on the orange button at the bottom of the...

Page 19: ...18 CONTROLLING YOUR DEVICE THROUGH THE APP THE HOME SCREEN Add a device Choose the device to control Smart Scenes Automation User Profile...

Page 20: ...e Change the operating mode between Smart dehumidify Air purify and laundry Desired Humidity Change the desired humidity between 35 C and 80 C Oscillation Set the position of the louvres Room Humidity...

Page 21: ...preset configurations Below is an example of how to set up a scene 1 Press on the Smart Scene tab at the bottom of the Home screen 3 Select Scene to create a new Scene 2 Press on the Plus in the top...

Page 22: ...ext to Please Enter Scene Name to input the name for your Scene Press the Red Plus next to When any condition is satisfied to add the trigger Press the Red Plus next to Execute following actions to ad...

Page 23: ...ou are also able to change settings related to the app itself CONNECTION TROUBLESHOOTING 1 Check whether the device is powered on and is in the correct standby mode if not please refer to the CHANGING...

Page 24: ...over gently approximately every 2 3 weeks If the mesh filter is dirty hoover it if it is heavily soiled wash it with warm soapy water and dry thoroughly before reinserting it in the unit When filter c...

Page 25: ...re a distance of at least 20 cm between the unit walls Airflow seems weak Are the filters dirty or clogged Please service the filters regularly as per the user manual Unit is noisy during operation Is...

Page 26: ...ll stop working while in dehumidifying mode unit may be defrosting The ambient operating range is between 5 C and 35 C with a relative humidity ranging from 30 to 80 For maximum efficiency use the uni...

Page 27: ...Elland West Yorkshire HX5 9DA Recycling facilities are now available for all customers at which you can deposit your old electrical products Customers will be able to take any old electrical equipmen...

Reviews: