ElectrIQ CD12LEB User Manual Download Page 6

 

 

 

INSTALLATION  

 

Remove any water from within the water tank before starting the unit. In order to save energy do not open windows 

or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit continuously for 

24 hrs. 

 

 

 

TO REDUCE NOISE LEVELS: 

 

Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running. 

 

 

 

The CD12LE and CD20LE dehumidifiers use compressor technology to extract water from the 

environment. Compressor dehumidifiers are ideal for normal domestic or office environments which are 

heated during the winter months and maintain a temperature above 12-

15⁰C.  

The dehumidifiers are easy to move around on castors and are designed to extract unwanted humidity 

while saving money due to their power-saving logic. They feature an intelligent humidistat where the 

desired relative humidity can be adjusted in increments of 5% between 40 and 80% ensuring your room is 

not dried too much and power is not wasted.  

FEATURES 

 

Your dehumidifier belongs to the electriQ low energy premium dehumidifiers featuring low power consumption, power-

saving logic and advanced air purification option.  

 

1.

 

Easy to use controls 

 

2.

 

Low energy only uses a fraction of the electricity of similar dehumidifiers 

 

3.

 

Great for up to 3 bed (CD12LEB) and 5 bed (CD20LE) houses 

 

4.

 

A cost-effective way to combat mould, condensation and damp 

 

5.

 

Dries laundry more efficiently than a tumble dryer  

 

6.

 

Designed to complement any modern space 

 

7.

 

Low and High fan speed selection for the best balance between running quiet and maximum water extraction 

 

8.

 

Anti-dust self-closing oscillating louvres for improved airflow 

 

9.

 

Castors for improved mobility 

 

10.

 

Intelligent CPU controlled digital humidistat with 35-80% RH and room humidity display 

 

11.

 

24-hour start / stop timer 

 

12.

 

Tank operation or permanent drainage option with splash-proof tank 

 

13.

 

Tank full alarm & auto-stop function 

 

14.

 

Air purifier function with UV sterilisation 

 

 

 

Summary of Contents for CD12LEB

Page 1: ...R PURIFIER CD12LEB 12 Litres per day CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future refere...

Page 2: ...1 CONTENTS SAFETY INSTRUCTIONS 2 INSTALLATION 5 PARTS 6 CONTROL PANEL 7 QUICK REFERENCE GUIDE 8 POSITIONING 11 WATER DRAINAGE 12 CARE AND MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL DATA 15...

Page 3: ...r connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the cord power...

Page 4: ...y qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained...

Page 5: ...4 QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER...

Page 6: ...adjusted in increments of 5 between 40 and 80 ensuring your room is not dried too much and power is not wasted FEATURES Your dehumidifier belongs to the electriQ low energy premium dehumidifiers featu...

Page 7: ...ed carbon filter Optional Louvres 1 Air Outlet 3 2 Handle 4 Humidity Indicator light Wheels 5 6 Control Panel 7 Pre filter activated 8 Air inlet Carbon filter 9 Continuous Drain Port 10 Back Cover 11...

Page 8: ...d aim for the humidity set using the up and down buttons FAN Only the fan will run and water is not extracted Use with the UV function for improved air purification HUMIDITY INDICATOR MODE When the ap...

Page 9: ...e is running with the desired settings press the TIMER button then use the UP and DOWN buttons to set in how many hours time you require the unit to stop 0 24 hours INTELLIGENT DEFROST The appliance w...

Page 10: ...e room ensuring the entire air in the room is processed and humidity correctly measured To achieve drier air or while drying laundry put the unit in High mode and use the down button to select a lower...

Page 11: ...the fan will continue to operate to ensure that the air within the room is not stale The unit will use only a minimal amount of energy in fan mode When the humidity of the room is equal to or higher...

Page 12: ...on for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and...

Page 13: ...ll the way into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosur...

Page 14: ...e NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be reinserted securely into dehumidifier in order to restart operation END OF SEASON MAINTENANCE 1 Empty and cl...

Page 15: ...tructions and restart the unit Ensure a distance of at least 20 cm between the unit walls Airflow seems weak Is filter dirty or clogged Please service the filters regularly as per user manual Unit is...

Page 16: ...gs 14 14 3 GWP 3 3 All information provided is for reference only Products specifications may change due to continuous product development Disposal Do not dispose of this product as unsorted waste Col...

Page 17: ...ugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full 6 Was the troubleshooting guide fo...

Reviews: