OTHER FEATURES AND INDICATORS 

 

 

TANK FULL LIGHT

 

 

When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, the red tank full light 

will illuminate and the unit will beep.  Empty the tank and reinsert it correctly to resume operation.  

 

 

AUTO DEFROST  

When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost mode.  

Following the completion of the defrost mode, the unit will return to the previously operating settings. 

 

 

When the unit is running in a room with a temperature between 5

o

C and 12

o

C, it will enter defrost mode 

roughly every 30 minutes. 

 

 

When the unit is running in a room with a 

temperature between 12⁰C and 20⁰C, it will enter the defrost 

mode roughly every 45 minutes.  

 

HUMIDISTAT CONTROL AND FAN/COMPRESSOR OPERATION

 

 

 

When  the  humidity  of  the  room  is  2%  lower  than  the  desired  humidity  the  compressor  will  turn  off 
automatically but the fan will continue to operate to ensure that the air within the room is not stale. The 
unit will use only a minimal amount of energy in fan mode. 

 

 

When the humidity of the room is equal to or higher than the desired humidity the compressor will restart 
after a 3 minutes delay to protect the compressor. 

 

 

AUTO-RESTART (on some models)  

If the unit stops unexpectedly due to the power cut, it will restart with the previous function selected automatically 

when the power resumes, and the 3-minute compressor protection has elapsed.

 

 

POWER

 

 

After the unit has stopped, to protect the compressor it is not recommended to resume operation for at least 10 

minutes. Operation can resume after this period lapses. When the unit is restarted there is a 3 minutes delay 
before the compressor will start. 

 

 

LIGHTWEIGHT PORTABLE DESIGN ON CASTORS

 

 

The dehumidifier is built to be compact and lightweight. The castors on the bottom of the unit make it easy to 

move from room to room.  

 

Your dehumidifier contains an advanced micro-CPU controlled device which is capable of self-diagnostics. The 

LCD display may also show the error and protection codes.  

 

 

 

 

 

 

 

Summary of Contents for CD12LEB

Page 1: ...R PURIFIER CD12LEB 12 Litres per day CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future refere...

Page 2: ...1 CONTENTS SAFETY INSTRUCTIONS 2 INSTALLATION 5 PARTS 6 CONTROL PANEL 7 QUICK REFERENCE GUIDE 8 POSITIONING 11 WATER DRAINAGE 12 CARE AND MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL DATA 15...

Page 3: ...r connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the cord power...

Page 4: ...y qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained...

Page 5: ...4 QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER...

Page 6: ...adjusted in increments of 5 between 40 and 80 ensuring your room is not dried too much and power is not wasted FEATURES Your dehumidifier belongs to the electriQ low energy premium dehumidifiers featu...

Page 7: ...ed carbon filter Optional Louvres 1 Air Outlet 3 2 Handle 4 Humidity Indicator light Wheels 5 6 Control Panel 7 Pre filter activated 8 Air inlet Carbon filter 9 Continuous Drain Port 10 Back Cover 11...

Page 8: ...d aim for the humidity set using the up and down buttons FAN Only the fan will run and water is not extracted Use with the UV function for improved air purification HUMIDITY INDICATOR MODE When the ap...

Page 9: ...e is running with the desired settings press the TIMER button then use the UP and DOWN buttons to set in how many hours time you require the unit to stop 0 24 hours INTELLIGENT DEFROST The appliance w...

Page 10: ...e room ensuring the entire air in the room is processed and humidity correctly measured To achieve drier air or while drying laundry put the unit in High mode and use the down button to select a lower...

Page 11: ...the fan will continue to operate to ensure that the air within the room is not stale The unit will use only a minimal amount of energy in fan mode When the humidity of the room is equal to or higher...

Page 12: ...on for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and...

Page 13: ...ll the way into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosur...

Page 14: ...e NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be reinserted securely into dehumidifier in order to restart operation END OF SEASON MAINTENANCE 1 Empty and cl...

Page 15: ...tructions and restart the unit Ensure a distance of at least 20 cm between the unit walls Airflow seems weak Is filter dirty or clogged Please service the filters regularly as per user manual Unit is...

Page 16: ...gs 14 14 3 GWP 3 3 All information provided is for reference only Products specifications may change due to continuous product development Disposal Do not dispose of this product as unsorted waste Col...

Page 17: ...ugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full 6 Was the troubleshooting guide fo...

Reviews: