ElectrIQ CD12LEB User Manual Download Page 10

 

 

 

QUICK REFERENCE GUIDE  

 
 Power Button: 

Press to turn the dehumidifier on and off.   

 
 

 Oscillation Button: 

Press once to make the louvre swing and press again to lock at 45 degrees, 

press again to lock at 90 degrees. Do not operate the unit if the self-opening louvres do not open on 
power on.  

 
Timer

: Press the timer button, then use the   

buttons to adjust the duration of the 

timer (1-24 hrs, start/ stop timer).  
 

If  set while the unit is running

: The number will represent the number of hours the  unit will operate before 

turning off. This will not be affected if the unit enters defrost mode or the tank is emptied and reinserted.  

 

If set while the unit is in standby:

 the set number represents the period in hours after which the unit will start. 

To cancel the start / stop mode press the timer key again.  

 

Up and Down Buttons:

 

During the High or Low modes when the unit is displaying the 

current relative humidity, these buttons can be used to adjust the desired humidity level. 
The desired relative humidity can be set between 35 and 80% in 5% increments.   

 

SMART Mode:

 This is designed for maximum convenience and maintains the ideal 

domestic environment humidity level of 50-55% while saving electricity. This is the 
default mode and is recommended for most users. 
  

 

During use, the compressor will operate until the desired humidity is reached and then will stop.  The economical 

low fan mode will continue to operate. The fan moves the air around the room ensuring the entire air in the room 
is processed and humidity correctly measured.  

 

 
To achieve drier air, or while drying laundry, put the unit in High mode and use the down button to select a lower 

desired humidity (e.g. 35-45%). 

 

 

LAUNDRY MODE:

 When drying clothes, it is advised for the dehumidifier to operate continuously with maximum 

water extraction until the  water tank is full. Set  the  unit to the High mode, and set the  desired humidity level 
between 35%-50%. 35% is very dry and is hardly achievable in a UK domestic environment. As such the unit will 
work until water tank is full when set to 35%. Set the louvres to swing mode or to 45 degrees directing the airflow 
onto the clothes. Do not place clothes directly over any of the vents on the dehumidifier. Make sure that there is 
nothing  blocking  the  hot  air  exhaust  airflow  and  for  best  results  place  the  laundry  within  1.5  meters  of  the 
dehumidifier.  

 

NOTES:  

 

If a permanent drainage pipe is fitted the unit will not stop operating. Setting the desired humidity to around 
35% is good for laundry mode, a quick-drying boost, or in emergencies. It is not recommended for long 
operation in a domestic or office environment. 

 

 

To allow more moisture in the air, press the up button and set to a higher desired humidity (e.g. 60-70%). 

 

 

We recommend setting the Humidity to 50-55%.  This is great for domestic operation and dry storage

 

 

Setting the humidity to 60% is great for personal comfort and applications where 50% RH is considered 
too dry 

 

 

Setting  the  humidity  to  70%  is  ideal  for  unoccupied  properties  or where  an  economical  run  is  needed 
without the need to reduce the humidity further. 

 

 

 

 

 

 

 

Summary of Contents for CD12LEB

Page 1: ...R PURIFIER CD12LEB 12 Litres per day CD20LEB 20 Litres per day Thank you for choosing electriQ Please read this user manual before using this innovative dehumidifier and keep it safe for future refere...

Page 2: ...1 CONTENTS SAFETY INSTRUCTIONS 2 INSTALLATION 5 PARTS 6 CONTROL PANEL 7 QUICK REFERENCE GUIDE 8 POSITIONING 11 WATER DRAINAGE 12 CARE AND MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL DATA 15...

Page 3: ...r connect the unit to an electrical outlet using an extension cord If a power outlet is not available one should be installed by a qualified electrician Never operate this appliance if the cord power...

Page 4: ...y qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information contained...

Page 5: ...4 QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER...

Page 6: ...adjusted in increments of 5 between 40 and 80 ensuring your room is not dried too much and power is not wasted FEATURES Your dehumidifier belongs to the electriQ low energy premium dehumidifiers featu...

Page 7: ...ed carbon filter Optional Louvres 1 Air Outlet 3 2 Handle 4 Humidity Indicator light Wheels 5 6 Control Panel 7 Pre filter activated 8 Air inlet Carbon filter 9 Continuous Drain Port 10 Back Cover 11...

Page 8: ...d aim for the humidity set using the up and down buttons FAN Only the fan will run and water is not extracted Use with the UV function for improved air purification HUMIDITY INDICATOR MODE When the ap...

Page 9: ...e is running with the desired settings press the TIMER button then use the UP and DOWN buttons to set in how many hours time you require the unit to stop 0 24 hours INTELLIGENT DEFROST The appliance w...

Page 10: ...e room ensuring the entire air in the room is processed and humidity correctly measured To achieve drier air or while drying laundry put the unit in High mode and use the down button to select a lower...

Page 11: ...the fan will continue to operate to ensure that the air within the room is not stale The unit will use only a minimal amount of energy in fan mode When the humidity of the room is equal to or higher...

Page 12: ...on for your dehumidifier If possible leave interior doors ajar to allow air circulation Alternatively if you have a serious problem in one area you can begin by positioning the dehumidifier there and...

Page 13: ...ll the way into the unit Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate Do not remove any parts from the water tank or tank enclosur...

Page 14: ...e NOTE Do not use a dishwasher to clean the tank After cleaning and drying the tank must be reinserted securely into dehumidifier in order to restart operation END OF SEASON MAINTENANCE 1 Empty and cl...

Page 15: ...tructions and restart the unit Ensure a distance of at least 20 cm between the unit walls Airflow seems weak Is filter dirty or clogged Please service the filters regularly as per user manual Unit is...

Page 16: ...gs 14 14 3 GWP 3 3 All information provided is for reference only Products specifications may change due to continuous product development Disposal Do not dispose of this product as unsorted waste Col...

Page 17: ...ugged into the mains 3 Is the fuse OK 4 Switch the unit off and wait three minutes to see if the issue is resolved Restart the unit 5 Check if the water tank is full 6 Was the troubleshooting guide fo...