current and voltage values will be displayed during welding.
If necessary, during welding, adjust current.
C - Hot Start:
Adjust hot start time on knob 3 between 0 and 1 seg. to increase initial current and optimize arc ignition.
This function is used specially for low current welding jobs.
D - Arc Force:
Adjust arc force with knob 6 between 0 and 100% welding current to avoid electrode sticking.
TIG WELDING
A - TIG welding process selection:
With machine connected, press key button 5 (led 4 lights on).
B - TIG Lift Arc selection :
Press key button 8 (led 7 lights off ).
C - TIG HF (high frequency) selection :
Press key button 8 (led 7 lights on).
D - 2T or 4T mode selection:
Press key button 11 for 2T mode; led 10 lights off or 4T mode; led 10 lights on.
E - Adjusting TIG parameters :
E.1 - Gas pre-flow : Adjust gas pre-flow time on knob 2 between 0,1 and 2,3 sec.,
press key button 5 during 1 second, until led 3 twinkles. Gas pre-flow time is programmed.
During working, led 3 (gas pre-flow) lights on during selected time.
Note: In Lift Arc mode, gas pre-flow is adjusted manually by the operator.
E.2 - Gas post-flow : Adjust gas post-flow time on knob 13 between 0,3 and 13 seconds,
press key button 11 during 1 second, until led 12 twinkles. Gas post-flow
time is programmed. During welding, led 12 (gas post-flow) lights on during
selected time.
E.3 - Up-slope: Adjust up-slope time with knob 2 between 0,3 and 10 seconds.
E.4 - Down-slope: Adjust down-slope time with knob13 between 0,3 and 28 seconds. During down-slope it is
possible to return to main current by pressing the torch trigger.