2-4
PRODUCT DATA SHEET
Revision Y05-01
Service Manual - DNC Series
DNC 955
-3PH R407C
Model
Ceiling Mounted
Installation method
Heating
Cooling
Units
Characteristic
30000
30000
Btu/hr
8790
8790
W
Capacity
3030
3370
W
Total input
2.9
2.61
W/W
COP
400
V/50Hz/
3
Power supply (voltage, cycle, No of phases)
3x8.0
3x8.9
A
Rated current
3x10
A
Circuit breaker rating
Plug Fan x 1
Fan type & qty.
500
5
5
0
700
RPM
Fan speed (HI-M-LO)
1
20
0
1
33
0
1700
m³/hr
705
780
1000
CFM
Airflow (LO-M-HI)
2
0-80
Pa
Static Pressure
51.3
54.8
57.2
dBA
Noise Power**
44.6
47.5
51.8
dBA
Noise Pressure*
3.1
l/h
Dehumidification
16
mm
Condensate drain tube I.D
1025
mm
W
Dimensions
760
mm
D
300
mm
H
43
Kg
Weight
1125x975x360
(Unit)+1180x870x180(Frame)
mm
Package dimensions
I
N
D
O
O
R
U
N
I
T
7
units
Stacking height
7
units
Units per palet
Capillary Tube
Refrigerant control
SCROLL
H
Q040
Y
Compressor type & model
Axial
Fan type & qty.
850
RPM
Fan speeds
3
1
00
m³/hr
1820
CFM
Airflow (std. conditions)
62
/
69
dBA
Noise Pressure*/ Noise Power
900
mm
W
Dimensions
340
mm
D
860
860
mm
H
8
2
Kg
Weight
903x985x406
mm
Packing dimensions
2
units
Stacking height
6
units
Units per palet
R
407C
Refrigerant
Charge for 7.5 meter pipes length
O
U
T
D
O
O
R
U
N
I
T
16
mm
Condensate drain tube I.D
3/8”
in.
liquid
5/8”
in.
suction
10
m
height difference
Connection between units
30
m
m
tubing length
T
U
B
E
S
LCD Remote Control
Operation control type
2x750
W
Heating elements
8”,10”,12”
Ducts
Crankcase heater 60W,3PH Protector
Others
A
C
C.
* Noise pressure tested at 1m distance from unit
** Noise power for ducted units measured at air outlet side
Grams
2530