Electra APE.1S1.x&x Installation Instructions Manual Download Page 6

page 6/6

4.4  programming the additional indoor terminals

If the installation contains just 1 indoor terminal, these steps are not necessary.

All indoor terminals leave the producer with address 1.
The main indoor terminal will 

nOT

 be programmed.

Operatorul 1 is programming from the main outdoor panel (address 1).

Operator 1

 

Main outdoor panel

Steps

Operator 2

 

Additional terminal

step 0

All LEDs are off.

ENTERING

programming mode

Operator 1 will hear [

BEEEEEEEEP

] in the outdoor 

panel.  Afterwards proceed to Step 2.

step 1

Press both keys 

 

 at the same time and 

hold until Operator 1 is done programming

*

.

You will hear the first [

BEEP

] by touching the two keys and 

the second [

BEEP

] when the terminal has been programmed

  Hold the keys pressed until you hear 

 

the second 

[

BEEP

]

!

ENTERING

programming mode

step 2

Press the apartment’s key, as many times as it 

is shown in the table below: 
( for every key you press you hear: [

BEEP

]  )

Operator 2

Main Additional 1 Additional 2 Additional 3

Indoor 

terminal

 

×2

 

(twice)

 

×3

 

(three times)

 

×4

 

(four times)

Red/White LED

during programming mode

Keep holding the keys 

pressed!

EXITING

programming mode

step 3

The panel makes a [

BEEP

] for confirmation.

step 3

You will hear 

the second

 [

BEEP

]. 

You can now release the keys!

EXITING

programming mode

You have succesfully programmed an indoor terminal.

Call to check!

We encourage you to program the additional indoor terminals at the head office. 

With the devices laid out on a table, one operator follows the same steps.

Label the devices you program so you don’t misplace them in the installation.

4.5  functions and adjustments

1. Check

 anywhere within the installation, during the 

call and the communication, that the power tension 

between 

+14 V

 

 

GND

 is higher than 

12,0 V

.

2. Check

 the functions of the indoor terminals and the outdoor 

panels: call, communication, access, audio monitoring.
When calling from outside, all indoor terminals will ring, but 

just the one you answer from can be used during the call.

The installation has been adjusted by the producer for audio 
communication to suit standard functioning conditions.

how to adjust the volume of the indoor terminal:

When the 

 LED is Red, the terminal is silent.

By pressing the  

 key you change between 

different volume levels (White LED).

 After the verifications, leave the indoor terminal on Open Volume: 

 

 white LED on.

how to choose the terminal’s ringtone:

1. Simultaneously press and hold keys: 

 

 !

2. Release the keys a few seconds after 

 begins flashing Red/White!

3. Press 

 to switch between ringtones.

4. Press 

 to set the ringtone.

Reviews: