Electra APE.1S1.x&x Installation Instructions Manual Download Page 4

page 4/6

3  elecTrical cOnnecTiOns

3.1  installation connections

SAC.V1A.DIN

ATE.Sxx

ATE.Sxx

ATB.Sxx

APE.1Sx

APE.1Fx

F

N

+14 V

GND
C/D

(DATA)

-Uv
GNV
Vin

+14 V

GND

C/D

(DATA)

+Uv
GNV

Vin

+14 V

GND

C/D

Dbl

+14 V

GND

C/D

+14 V

GND

C/D

AUX

BUT

LC
LA/C
LA

-ACC
+ACC

UTP CAT5

(AWG 24)

UTP CAT5

(AWG 24)

UTP CAT5

(AWG 24)

ACC

12 V/1,3 Ah

2 x 0,5 mm

2

Cable

3 x 0,75 mm

2

Cable

(Optional)

Electrical panel

Door 

opening 

button

Auxiliary

command

(Open collector)

BLUE

BLUE

BLUE

BROWN

BROWN

BROWN

ORANGE

ORANGE

ORANGE

GREEN

GREEN

GREEN

Indoor terminal 

additional

Indoor terminal

Main

Power Supply

Outdoor panel

230 Va.c./50Hz

Accumulator

(Optional)

Electro-

magnetic

Lock

AC

DC

+14 V

GND

C/D

DBL

(Optional)

Doorbell 

button

Indoor terminal

Main

3.2  lock connections

Drive current (DC)

BUT
LC
LA/C

LA

YEM.22x

BY

+Y

Y

Electromagnetic lock

Drive Current (DC)

3 x 0,5 mm

2

Cable

Outdoor panel

...

GND

...

BUT
LC
LA/C

LA

YEM.21x

GND

BY

+Y

Y

Electromagnetic lock

Drive Current (DC)

4 x 0,5 mm

2

Cable

Outdoor panel

Alternative current (AC)

YEM.32x

 BY  Y2 Y1

BUT

LC

LA/C

LA

Transformer

Electromagnetic lock

Alternative current (AC)

Outdoor panel

12 Va.c.

230 Va.c.

2 x 0,5 mm

2

Cable

BUT

LC

LA/C

LA

Electromagnetic lock

Alternative current (AC)

Outdoor panel

12 Va.c.

230 Va.c.

Transformer

2 x 0,5 mm

2

Cable

hub details

+14 V

+

 (+14 V d.c.; 2A) general feed of the installation

(except for video communication)

GND

0 V

 (mass) general feed of the installation

C/D

  audio and data communication

+Uv

+

 monitor display feed (+14 V d.c.)

-Uv

0 V

 (mass) monitor display feed

GNV

0 V

 (mass) video signal reference

Vin

(1 V vv) video signal input (also valid for V1, V2, V3 and V4)

Vout

(1 V vv) video signal output  

Ucam

+

 (+12 V d.c.; 0,2 A) external video camera feed

AUX

auxiliary command output (open collector)

Dbl

connection for a doorbell button

BUT

connection for opening the lock

LC

DC lock command

LA/C

DC/AC lock common

LA

AC lock command

+ACC

+

 accumulator connection (+12V; max. 7 Ah)

-ACC

-

 accumulator connection

F

phase (230 V a.c. / 50 Hz)

N

null
earthing

Hubs specific to 

ELECTRA

 locks

BY

connection for opening the lock

+Y

feed for Electra DC lock

Y

Y1

feed for Electra AC lock

Y2

Recommendation:

Connection to the grounding system: locally or 
from the distance (cable 1 x 0,75 mm2).

Reviews: